Skip to content
OpenAdvisories
Medium · 6.3 CVE-2025-40594 EUVD-2025-27242GHSA-jg6x-p73x-m4hc

A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS…

Published Sep 9, 2025 · Updated Mar 10, 2026 · Assigned by siemens

Description

A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.

Affected products

VendorProductAffectedFixed
Siemens SINAMICS G220 V6.4 < V6.4 HF2 V6.4 HF2
Siemens SINAMICS S200 V6.4 < V6.4 HF7 V6.4 HF7
Siemens SINAMICS S210 V6.4 < V6.4 HF2 V6.4 HF2

Advisories 3