Description

Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a telnet-based service
on port 23 to allow management operations such as firmware upgrades and
device reboots, which require authentication. A user with protected
privileges can successfully invoke the SetSerialPort functionality to
modify relevant device properties (such as serial interface settings),
contradicting the security model proposed in the user manual.

Affected products

VendorProductAffectedFixed
Cognex In-Sight 2000 series 5.x – ≤ 6.5.1 —
Cognex In-Sight 7000 series 5.x – ≤ 6.5.1 —
Cognex In-Sight 8000 series 5.x – ≤ 6.5.1 —
Cognex In-Sight 9000 series 5.x – ≤ 6.5.1 —
Cognex In-Sight Explorer 5.x – ≤ 6.5.1 —