Skip to content
OpenAdvisories
High · 7.2 CVE-2026-127122 EUVD-2026-125302GHSA-9cfr-5cg8-55x5

Out-of-bounds write with too many MCR blocks in a Connect request

Published Nov 13, 2026 · Updated Nov 13, 2026 · Assigned by rt-labs

Description

P-Net before 1.0.4 does not check the number of MCR request blocks in a Connect request against the number of multicast communication relations that an Application Relationship has room for (PNET_MAX_MC_CR, 1 by default). Each further block is written past the end of the array, into the rest of the Application Relationship and, with more blocks, into the following one. The written data comes from the request. No established Application Relationship is needed, and the attacker requires ADJACENT network access. Builds with PNET_OPTION_MC_CR disabled are not affected.

Affected products

VendorProductAffectedFixed
RT-Labs P-Net < 1.0.4 1.0.4

References