Skip to content
OpenAdvisories
High · 7.5 CVE-2026-2250 EUVD-2026-7030GHSA-fmxw-gfwm-67w3

Unauthenticated Data Export and Source Code Disclosure via /dbviewer/ in METIS WIC

Published Feb 11, 2026 · Updated Feb 12, 2026 · Assigned by MHV

Description

The /dbviewer/ web endpoint in METIS WIC devices is exposed without authentication. A remote attacker can access and export the internal telemetry SQLite database containing sensitive operational data. Additionally, the application is configured with debug mode enabled, causing malformed requests to return verbose Django tracebacks that disclose backend source code, local file paths, and system configuration.

Affected products

VendorProductAffectedFixed
METIS Cyberspace Technology METIS WIC oscore 2.1.234-r18 oscore 2.1.235-r19