Skip to content
OpenAdvisories
High · 7.1 CVE-2026-33892 EUVD-2026-22242GHSA-24c7-prh7-m3g7

A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pr…

Published Apr 14, 2026 · Updated Apr 14, 2026 · Assigned by siemens

Description

A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.
This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.
Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.

Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.

Affected products

VendorProductAffectedFixed
Siemens Industrial Edge Management Pro V1 V1.7.6 – < V1.15.17 V1.15.17
Siemens Industrial Edge Management Pro V2 V2.0.0 – < V2.1.1 V2.1.1
Siemens Industrial Edge Management Virtual V2.2.0 – < V2.8.0 V2.8.0

Advisories 4

References