Description
PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.
Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.
Affected products
| Vendor | Product | Affected | Fixed |
|---|---|---|---|
| Paessler | PRTG Network Monitor | < 26.2.120.1449 | 26.2.120.1449 |
Advisories 1
- WID-SEC-2026-3565 Paessler PRTG: Mehrere Schwachstellen BSI CERT-Bund (WID) · Sep 24, 2026
References
- https://r.sec-consult.com/paessler third-party-advisory
- https://paessler.freshdesk.com/en/support/solutions/articles/76000088640 vendor-advisory
- https://www.paessler.com/de/download/ patch
- https://www.paessler.com/prtg/prtg-network-monitor product