Skip to content
OpenAdvisories
Medium ICSA-26-211-11 2 CVEs

MZ Automation lib60870

Published Jul 30, 2026 · Updated Jul 30, 2026

Summary

Successful exploitation of these vulnerabilities could crash the device being accessed.

Vulnerabilities 2

  • Medium 6.5

    MZ Automation lib60870 Out-of-bounds Read

    A crafted IEC 60870-5-104 I-frame with TypeID 104 (C_TS_NA_1) and an inflated object count causes TestCommand_getFromBuffer to read one byte past the end of the heap-allocated message buffer.

  • Medium 6.5

    MZ Automation lib60870 Out-of-bounds Read

    A crafted IEC 60870-5-104 I-frame with a declared object count exceeding what fits in the ASDU body causes InformationObject_ParseObjectAddress to read one byte past the end of the heap-allocated message buffer.

Revision history

  1. #1

    Initial Publication

References