Archive
17 January 2015
Vulnerabilities first published on this day (UTC), newest first.
14 results · Feed
-
Unscored —
Ceragon FibeAir IP-10 bridges have a default password for the root account, which makes it easier for remote attackers …
-
Unscored —
Cisco WebEx Meeting Center allows remote attackers to activate disabled meeting attributes, and consequently obtain sen…
-
Unscored —
IBM ServerGuide before 9.63, UpdateXpress System Packs Installer (UXSPI) before 9.63, and ToolsCenter Suite before 9.63…
-
Unscored —
IBM Security Network Protection 5.1.x and 5.2.x before 5.2.0.0 FP5 and 5.3.x before 5.3.0.0 FP1 allows remote attackers…
-
Unscored —
IBM BladeCenter SAS Connectivity Module (aka NSSM) and SAS RAID Module (aka RSSM) before 1.3.3.006 allow remote attacke…
-
Unscored —
Cross-site scripting (XSS) vulnerability in the Web GUI in IBM Tivoli Netcool/OMNIbus 7.3.0 before 7.3.0.6, 7.3.1 befor…
-
Unscored —
IBM BladeCenter SAS Connectivity Module (aka NSSM) and SAS RAID Module (aka RSSM) before 1.3.3.006 allow remote attacke…
-
Medium 6.6
GE Proficy HMI/SCADA CIMPLICITY CimView
The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file.
-
Unscored —
Samba 4.0.x before 4.0.24, 4.1.x before 4.1.16, and 4.2.x before 4.2rc4, when an Active Directory Domain Controller (AD…
-
Critical 10.0
Phoenix Contact Software ProConOs and MultiProg Missing Authentication for Critical Function
Phoenix Contact ProConOs and MultiProg do not require authentication, which allows remote attackers to execute arbitrary commands via protocol-compliant traffic.
-
Medium 5.4
Arbiter Systems 1094B GPS Clock Insufficient Verification of Data Authenticity
Arbiter 1094B GPS Substation Clock allows remote attackers to cause a denial of service (disruption) via crafted radio transmissions that spoof GPS satellite broadcasts.
-
Critical 10.0
Clorius Controls A/S ISC SCADA Insecure Java Client Inadequate Encryption Strength
The Clorius Controls Java web client before 01.00.0009g allows remote attackers to discover credentials by sniffing the network for cleartext-equivalent traffic.
-
Medium 5.0
GE Multilink Uncontrolled Resource Consumption
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via c…
-
Critical 10.0
GE Multilink Use of Hard-coded Cryptographic Key
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it eas…