Critical 10.0
RVD#2569: Insecure operating system defaults in MiR robots
MiR robot controllers (central computation unit) makes use of Ubuntu 16.04.2 an operating system, Thought for desktop uses, this operating system presents insecure defaults for robots. These insecurities include a way for users to escalate their access beyond…
-
Critical 9.8
RVD#2566: Hardcoded Credentials on MiRX00 wireless Access Point
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSI…
-
Critical 9.8
RVD#2565: Weak token generation for the REST API.
The access tokens for the REST API are directly derived from the publicly available default credentials for the web interface. Given a USERNAME and a PASSWORD, the token string is generated directly with base64(USERNAME:sha256(PASSWORD)). An unauthorized atta…
-
Critical 9.8
RVD#2557: Hardcoded Credentials on MiRX00 Control Dashboard
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users…
-
Critical 9.8
RVD#2558: Default credentials on SICK PLC allows disabling safety features
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and a…
-
Critical 10.0
RVD#2555: MiR ROS computational graph is exposed to all network interfaces, including poorly secured wireless networks and open wired ones
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS …
-
Critical 10.0
RVD#2554: MiR ROS computational graph presents no authentication mechanisms
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the…