Category
ICS / OT
4,112 known vulnerabilities.
1,749 results · Clear filters · Feed
-
High 7.8
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targ…
-
High 8.8
CVE-2023-1141
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution.
-
High 7.5
CVE-2023-1142
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.
-
High 7.1
CVE-2023-1134
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges.
-
High 8.8
CVE-2023-1143
In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.
-
High 8.8
CVE-2023-1144
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.
-
High 7.5
CVE-2023-1138
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials.
-
High 8.8
CVE-2023-1139
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.
-
High 8.8
CODESYS: Exposure of Resource to Wrong Sphere in CODESYS V3
In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
-
High 8.8
Codesys Runtime Improper Limitation of a Pathname
The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device.
-
High 7.5CVE-2023-27857 EPSS 18%
Rockwell Automation ThinManager ThinServer Heap-Based Buffer Overflow
In affected versions, a heap-based buffer over-read condition occurs when the message field indicates more data than is present in the message field in Rockwell Automation's ThinManager ThinServer. An unauthenticated remote attacker can exploit this vulnerab…
-
High 7.5
Rockwell Automation ThinManager ThinServer Path Traversal Download
In affected versions, path traversal exists when processing a message of type 8 in Rockwell Automation's ThinManager ThinServer. An unauthenticated remote attacker can exploit this vulnerability to download arbitrary files on the disk drive where ThinServer.e…
-
High 7.8
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpret…
-
High 8.8
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that coul…
-
High 7.8
A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, pot…
-
High 8.8
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause mani…
-
High 7.8
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could…
-
High 8.8
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.3). The audit log form of affected applica…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.6
CVE-2023-1257
An attacker with physical access to the affected Moxa UC Series devices can initiate a restart of the device and gain access to its BIOS. Command line options can then be altered, allowing the attacker to access the terminal. From the terminal, the attacker c…
-
High 7.5
Information Disclosure Vulnerability in MELSEC Series
Plaintext Storage of a Password vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series, MELSEC iQ-R Series, MELSEC-Q Series and MELSEC-L Series allows a remote unauthenticated attacker to disclose plaintext credentials stored in project files and…
-
High 8.8
Improper authentication vulnerability in S+ Operations
Improper Authentication vulnerability in ABB Symphony Plus S+ Operations.This issue affects Symphony Plus S+ Operations: from 2.X through 2.1 SP2, 2.2, from 3.X through 3.3 SP1, 3.3 SP2.
-
High 8.8
Improper Authorization
The affected product DIAEnergie (versions prior to v1.9.03.001) contains improper authorization, which could allow an unauthorized user to bypass authorization and access privileged functionality.
-
High 7.8
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.254), Parasolid V34.1 (All versions < V34.…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…
-
High 7.8
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applicatio…