IGSS Data Server (IGSSdataServer.exe) at a glance
- Last 12 months
- 0
- Critical · all time
- 9
- Exploited · all time
- 0
- Public exploit · all time
- 0
Show as table
| Month | Vulnerabilities | Critical |
|---|---|---|
| Nov 2026 | 0 | 0 |
| Oct 2026 | 0 | 0 |
| Sep 2026 | 0 | 0 |
| Aug 2026 | 0 | 0 |
| Jul 2026 | 0 | 0 |
| Jun 2026 | 0 | 0 |
| May 2026 | 0 | 0 |
| Apr 2026 | 0 | 0 |
| Mar 2026 | 0 | 0 |
| Feb 2026 | 0 | 0 |
| Jan 2026 | 0 | 0 |
| Dec 2025 | 0 | 0 |
| Nov 2025 | 0 | 0 |
| Oct 2025 | 0 | 0 |
| Sep 2025 | 0 | 0 |
| Aug 2025 | 0 | 0 |
| Jul 2025 | 0 | 0 |
| Jun 2025 | 0 | 0 |
| May 2025 | 0 | 0 |
| Apr 2025 | 0 | 0 |
| Mar 2025 | 0 | 0 |
| Feb 2025 | 0 | 0 |
| Jan 2025 | 0 | 0 |
| Dec 2024 | 0 | 0 |
Latest advisories
-
High max 8.8ICSA-23-082-04 8 CVEs
Schneider Electric IGSS
Successful exploitation of these vulnerabilities could result in a denial-of-service condition, as well as the loss, addition, or modification of dashboards or report files in the IGSS Report folder. Successful exploitation of these vulnerabilities could also…
-
Critical max 9.8
IGSS (Interactive Graphical SCADA System)
Schneider Electric is aware of multiple vulnerabilities in its Data Server module for the IGSS (Interactive Graphical SCADA System) product. The IGSS product is a SCADA system used for monitoring and controlling industrial processes. The Data Server is a modu…
first Jun 14, 2022 -
Critical max 9.8
IGSS (Interactive Graphical SCADA System)
Schneider Electric is aware of a vulnerability in its Data Server module for the IGSS (Interactive Graphical SCADA System) product. The IGSS product is a state-of-the art SCADA system used for monitoring and controlling industrial processes. The Data Server i…
first Apr 12, 2022 -
CriticalICSA-22-046-01 8 CVEs
Schneider Electric IGSS
Successful exploitation of these vulnerabilities could result in a variety of issues, including disclosure of data and loss of control of the SCADA system with IGSS running in production mode.
-
CriticalSEVD-2022-039-01 8 CVEs
IGSS (Interactive Graphical SCADA System)
Schneider Electric is aware of multiple vulnerabilities in the IGSS (Interactive Graphical SCADA System) Data Server module. The IGSS product is a state-of-the art SCADA system used for monitoring and controlling industrial processes. The Data Server is a mod…
18 results · Feed
-
High 7.8
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpret…
-
High 8.8
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that coul…
-
Medium 6.5
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the …
-
Medium 6.5
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that coul…
-
High 7.8
A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, pot…
-
High 8.8
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause mani…
-
High 7.8
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could…
-
Medium 6.5
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause acce…
-
Critical 9.8
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overfl…
-
Critical 9.8
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to …
-
Critical 9.8
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overfl…
-
Critical 9.8
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overfl…
-
Critical 9.8
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overfl…
-
Critical 9.8
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overfl…
-
Critical 9.8
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overfl…
-
High 8.6
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and …
-
Critical 9.8
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overfl…
-
Critical 9.8
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overfl…