Category
ICS / OT
4,112 known vulnerabilities.
1,749 results · Clear filters · Feed
-
High 7.8
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.…
-
High 7.5
A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All vers…
-
High 8.1
A vulnerability has been identified in Mendix Email Connector (All versions < V2.0.0). Affected versions of the module …
-
High 8.8
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethe…
-
High 7.8
A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions <…
-
High 7.8
A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions <…
-
High 7.8
A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions <…
-
High 7.8
A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions <…
-
High 7.8
A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions <…
-
High 7.8
A vulnerability has been identified in JT2Go (All versions < V14.1.0.6), Teamcenter Visualization V13.2 (All versions <…
-
High 7.8
A vulnerability has been identified in Simcenter STAR-CCM+ (All versions < V2306). The affected application improperly …
-
High 7.8
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0). Affected software does not properly secure …
-
High 7.5
A vulnerability has been identified in SICAM PAS/PQS (All versions < V7.0), SICAM PAS/PQS (All versions >= 7.0 < V8.06)…
-
High 7.5
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an att…
-
High 7.8
Out-of-bounds write vulnerability exists in CX-Programmer v.9.77 and earlier, which may lead to information disclosure …
-
High 7.8
Use-after free vulnerability exists in CX-Programmer v.9.77 and earlier, which may lead to information disclosure and/o…
-
High 7.8
Stack-based buffer overflow vulnerability exists in CX-Programmer v.9.77 and earlier, which may lead to information dis…
-
High 8.6
Denial of Service (DoS) Vulnerability in MELSEC iQ-R Series Ethernet Interface Module
Improper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version "65" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware version "65" and prior al…
-
High 7.5
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z al…
-
High 8.6
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095…
-
High 7.1
Cleartext Credentials Vulnerability on Hitachi Energy’s Multiple IED Connectivity Packages (IED ConnPacks) and PCM600 Products
A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in …
-
High 7.5
A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet comm…
-
High 7.8
UC-8100A-ME-T System Image: Versions v1.0 to v1.6, UC-2100 System Image: Versions v1.0 to v1.12, UC-2100-W System Image…
-
High 7.5
A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the cont…
-
High 8.8
Input Validation Vulnerability in Hitachi Energy’s MicroSCADA Pro/X SYS600 Products
An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. An authenticated user can launch an administrator level remote code execution irrespective of the authenticated user's role.
-
High 8.8
Delta Electronics DIAEnergie SQL Injection
SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
-
High 8.8
Delta Electronics DIAEnergie SQL Injection
SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
-
High 8.8
Delta Electronics DIAEnergie SQL Injection
SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
-
High 8.8
Delta Electronics DIAEnergie SQL Injection
SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
-
High 8.8
Delta Electronics DIAEnergie SQL Injection
SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
-
High 7.5
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server ho…
-
High 7.5
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server ho…
-
High 7.5
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server ho…
-
High 7.5
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). An unauthenticated Server-Side Reque…
-
High 7.5
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server ho…
-
High 7.5
A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server ho…
-
High 7.8
Buffer Overflow in PHOENIX CONTACT Automationworx Software Suite
In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation mi…
-
High 7.8
Out-of-bounds Read in PHOENIX CONTACT Automationworx Software Suite
In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compr…
-
High 7.5
Denial-of-Service vulnerability in PHOENIX CONTACT mGuard product family
A remote, unauthenticated attacker could cause a denial-of-service of PHOENIX CONTACT FL MGUARD and TC MGUARD devices below version 8.9.0 by sending a larger number of unauthenticated HTTPS connections originating from different source IP’s. Configuring firew…
-
High 7.5
PHOENIX CONTACT: FL MGUARD DM version 1.12.0 and 1.13.0 Improper Privilege Management
In Phoenix Contact: FL MGUARD DM version 1.12.0 and 1.13.0 access to the Apache web server being installed as part of the FL MGUARD DM on Microsoft Windows does not require login credentials even if configured during installation.Attackers with network access…