Skip to content
OpenAdvisories

Product · Phoenix Contact

Config+

4 known vulnerabilities.

Config+ at a glance

Last 12 months
0
Critical · all time
1
Exploited · all time
0
Public exploit · all time
0
New vulnerabilities per month · last 12 months
0 1 1 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 0 vulnerabilities June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 0 vulnerabilities September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202600
Jul 202600
Jun 202600
May 202600
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202500
Aug 202500
Jul 202500
Jun 202500
May 202500
Apr 202500
Mar 202500
Feb 202500
Jan 202500
Dec 202400

Latest advisories

  • High max 7.5
    VDE-2023-057 1 CVE rev. 2

    Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC

    Phoenix Contact classic line industrial controllers are developed and designed for the use in closed industrial networks. The controllers don't feature a function to check integrity and authenticity of the application (e.g.: logic files, executable logic, con…

    first Dec 12, 2023
  • High max 7.8
    VDE-2022-048 2 CVEs rev. 3

    PHOENIX CONTACT: Automationworx BCP File Parsing Vulnerabilities

    Manipulated PC Worx or Config+ files could lead to a heap buffer overflow, release of unallocated memory or a read access violation due to insufficient validation of input data.The attacker needs to get access to an original bus configuration file (*.bcp) to …

    first Nov 15, 2022
  • High max 7.8
    VDE-2021-020 1 CVE rev. 3

    PHOENIX CONTACT: Security Advisory for Automation Worx Software Suite

    Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data (CWE-824). The attacker needs to get access to an original bus configuration file (*.bcp) to be able to man…

    first Jun 23, 2021
  • High
    VDE-2019-016 1 CVE rev. 3

    PHOENIX CONTACT: Security Advisory for Automation Worx Software Suite

    Manipulated PC Worx or Config+ projects could lead to a remote code execution due to insufficient input data validation. The attacker needs to get access to an original PC Worx or Config+ project to be able to manipulate data inside the project folder. After …

    first Oct 15, 2019
  • High
    VDE-2019-014 3 CVEs rev. 3

    PHOENIX CONTACT: Multiple Vulnerabilities in Automation Worx Software Suite

    A manipulated PC Worx or Config+ project file could lead to a remote code execution.\ The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation the attacker needs to exchange the original f…

    first Jun 19, 2019

4 results · Feed

  • High 7.5

    Phoenix Contact: Classic line industrial controllers prone to inadequate integrity check of PLC

    Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC.

  • Critical 9.8

    Phoenix Contact: Automation Worx and classic line controllers prone to Incorrect Permission Assignment for Critical Resource

    Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device.

  • High 7.8

    Buffer Overflow in PHOENIX CONTACT Automationworx Software Suite

    In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation mi…

  • High 7.8

    Out-of-bounds Read in PHOENIX CONTACT Automationworx Software Suite

    In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compr…