4,112 results · Feed
-
High 7.8
File Parsing Memory Corruption in CNCSoft-G2
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
-
High 7.8
File Parsing Memory Corruption in CNCSoft-G2
Delta Electronics CNCSoft-G2 lacks proper validation of the user-supplied file. If a user opens a malicious file, an attacker can leverage this vulnerability to execute code in the context of the current process.
-
High 7.5
S1 Agile Privilege Escalation
Improper Privilege Management vulnerability in GE Vernova S1 Agile Configuration Software on Windows allows Privilege Escalation.This issue affects S1 Agile Configuration Software: 3.1 and previous version.
-
Medium 6.8
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series Q0…
-
High 7.2
Authenticated File Disclosure/Delete
Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5.
-
High 7.2
Remote Code Execution
Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.A remote code execution is possible due to an improper input validation. This issue affects FLXEON: through 9.3.5.
-
High 8.8
Predictable Salt and Weak Hashing Algorithm
Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. and newer versions
-
High 7.0
Hardcoded passwords
Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions
-
Medium 6.7
Vulnerability caused by unquoted file paths of Windows services registered by the Uninterruptible Power Supply (UPS) management application
A vulnerability (CWE-428) has been identified in the Uninterruptible Power Supply (UPS) management application provided by OMRON SOCIAL SOLUTIONS Co., Ltd., where the executable file paths of Windows services are not enclosed in quotation marks. If the instal…
-
Medium 6.5
WAGO: Vulnerability in hardware switch circuit
During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration.
-
High 7.3CVE-2025-58320 EPSS 19%
DIALink - Directory Traversal Authentication Bypass Vulnerability
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
-
Critical 10.0
DIALink - Directory Traversal Authentication Bypass Vulnerability
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
-
Medium 5.8
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists…
-
Medium 5.8
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists…
-
Medium 5.3
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that …
-
High 7.3
Rockwell Automation FactoryTalk Optix Remote Code Execution Vulnerability
A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution.
-
High 8.6
Rockwell Automation Stratix® IOS Cross-Site Request Forgery to Code Execution Vulnerability
A security issue affecting multiple Cisco devices also directly impacts Stratix® 5410, 5700, and 8000 devices. This can lead to remote code execution by uploading and running malicious configurations without authentication.
-
High 8.6
Rockwell Automation ThinManager® Server-Side Request Forgery Vulnerability
A server-side request forgery security issue exists within Rockwell Automation ThinManager® software due to the lack of input sanitization. Authenticated attackers can exploit this vulnerability by specifying external SMB paths, exposing the ThinServer® servi…
-
High 8.7
Rockwell Automation FactoryTalk Activation Manager Lack of Encryption Vulnerability
A security issue exists within FactoryTalk Activation Manager. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise.
-
High 8.7
Rockwell Automation FactoryTalk® Analytics™ LogixAI® Exposed Redis DB
An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data.
-
High 8.2
Rockwell Automation ControlLogix® 5580 V35.013 Denial-Of-Service
A denial-of-service security issue exists in the affected product and version. The security issue stems from the controller repeatedly attempting to forward messages. The issue could result in a major nonrecoverable fault on the controller.
-
High 7.0
Rockwell Automation CompactLogix® 5480 Code Execution Vulnerability
A code execution security issue exists in the affected product. An attacker with physical access could abuse the maintenance menu of the controller with a crafted payload. The security issue can result in arbitrary code execution.
-
High 7.1
Rockwell Automation 1756-ENT2R, EN4TR, EN4TRXT Vulnerability
A security issue exists in the protected mode of 1756-EN4TR and 1756-EN2TR communication modules, where a Concurrent Forward Close operation can trigger a Major Non-Recoverable (MNFR) fault. This condition may lead to unexpected system crashes and loss of dev…
-
High 7.1
Rockwell Automation 1756-ENT2R, EN4TR, EN4TRXT Vulnerability
A security issue exists in the protected mode of EN4TR devices, where sending specifically crafted messages during a Forward Close operation can cause the device to crash.
-
High 7.8
Beckhoff: Deserialization of untrusted data by TwinCAT 3 Engineering
An unauthenticated attacker can trick a local user into executing arbitrary commands by opening a deliberately manipulated project file with an affected engineering tool. These arbitrary commands are executed in the user context.
-
Critical 9.1
A vulnerability has been identified in SIMATIC Virtualization as a Service (SIVaaS) (All versions). The affected applic…
-
Low 3.1
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions). The affected device exposes c…
-
Low 3.1
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions). The affected device may be su…
-
High 7.5
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATI…
-
High 7.5
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATI…
-
High 7.5
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATI…
-
Critical 9.8
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATI…
-
Medium 5.3
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All …
-
Medium 6.3
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions <…
-
High 7.5
Improper Permission Handling Enables Unauthorized Access to Firmware and Certificates
A low-privileged remote attacker could gain unauthorized access to critical resources, such as firmware and certificates, due to improper permission handling during the runtime of services (e.g., FTP/SFTP). This access could allow the attacker to escalate pri…
-
Medium 5.8
DIAView - Authentication Bypass Vulnerability
Delta Electronics DIAView has an authentication bypass vulnerability.
-
High 7.5
Information Disclosure Vulnerability in MELSEC iQ-F Series CPU module
Cleartext Transmission of Sensitive Information vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to obtain credential information by intercepting SLMP communication messages, and read or w…
-
High 7.3
Information Disclosure, Information Tampering, and Denial of Service (DoS) Vulnerability in MELSEC iQ-F Series CPU module
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to read or write the device values of the product and stop the operation of the programs, sinc…
-
High 7.8
COMMGR Code Injection Vulnerability
Delta Electronics COMMGR has Code Injection vulnerability.
-
High 8.6
COMMGR Stack-based Buffer Overflow Vulnerability
Delta Electronics COMMGR has Stack-based Buffer Overflow vulnerability.