Category
ICS / OT
4,112 known vulnerabilities.
4,112 results · Feed
-
High 7.5
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.3). The affected application is …
-
Medium 6.0
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.1). The affected application is …
-
High 7.8
A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.…
-
High 7.8
A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains …
-
High 7.8
A vulnerability has been identified in Simcenter Femap (All versions < V2606.0001). The affected applications contains …
-
Medium 4.3
A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.233.16-7862), Desigo PXC3 (All versions < V01…
-
High 7.8
A vulnerability has been identified in Simcenter Femap (All versions < V2606), Simcenter Nastran (All versions < V2606)…
-
Critical 10.0CVE-2026-58115 Public exploit
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running I…
-
Medium 6.8
A vulnerability has been identified in LOGO! Soft Comfort (All versions < V9). The project password feature in the affe…
-
Medium 6.8
A vulnerability has been identified in LOGO! Soft Comfort (All versions < V9). Affected products use a static, hardcode…
-
High 7.8
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All vers…
-
High 7.8
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All vers…
-
High 7.8
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All vers…
-
High 7.8
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All vers…
-
High 7.8
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All vers…
-
High 7.8
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All vers…
-
High 7.8
A vulnerability has been identified in Solid Edge SE2025 (All versions < V225.0 Update 15), Solid Edge SE2026 (All vers…
-
Critical 9.8
Command Injection in SCM (idledisconnect parameter)
Due to improper neutralization of special elements, an unauthenticated remote attacker is able to inject a command into the system configuration which is subsequently executed as root.
-
Critical 9.8
Firewall bypass during shutdown
Due to a flaw in the execution order of scripts during shutdown, the firewall is terminated prematurely during system shutdown. This creates a temporary window in which internal services may become externally accessible, potentially allowing an unauthenticate…
-
High 7.5
Exposed Reboot via Modbus
A reboot of the charging controller can be triggered via Modbus TCP without authentication. Therefore, when the Modbus functionality is enabled by opening the port that CharxModbusServer is listening, an unauthenticated attacker can perform a Denial-of-Servic…
-
Medium 6.6
Cleartext password in logs
The credentials for the local user "user-app" may be exposed in log files, potentially enabling a low-privileged local attacker with access to the logs to authenticate via SSH as the limited user "user-app". Charging could be interrupted.
-
High 7.8
Local Privilege Escalation vulnerability in /etc/init.d/user-applications via customer website file
A privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
-
Critical 9.8
ControllerAgent does not perform validation of firmware
The firmware update process for the basemodule of the charging controller only validates the CRC32 checksum without cryptographic signature verification. This allows an unauthenticated remote attacker to install a modified firmware, resulting in full system c…
-
Medium 5.3
JupiCore does not perform validation of firmware
An unauthenticated remote attacker can inject malicious firmware into the internal charging module because the JupiCore service transmits firmware updates without performing integrity or verification check. Successful exploitation may compromise the integrity…
-
Medium 5.3
OCPP Firmware download is not properly locked
An unauthenticated remote attacker can trigger a firmware update download via the OCPP backend by supplying an invalid firmware file. This will cause the file to remain accessible for a short period before it is deleted due to improper locking during the clea…
-
Critical 9.8
OCPP reconfiguration vulnerability
Due to missing authentication the CHARX OCPP Agent service allows an unauthenticated remote attacker to reconfigure the backend connection. This can lead to Denial-of-Service and confidential data being disclosed to the attacker.
-
Critical 9.4
JupiCore charging point reconfiguration without auth
The CHARX JupiCore service allows an unauthenticated remote attacker to reconfigure charging points. This can lead to disclosure of charging point UIDs, Denial-of-Service and files tampering.
-
High 7.8
Local Privilege Escalation via pppd password injection
A privilege escalation vulnerability in the system configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
-
High 8.6
OS Command Injection in OCPP Agent via charge_box_id
This vulnerability allows an unauthenticated remote attacker with control over the OCPP backend via firewall-bypass to perform an OS command injection, resulting in the execution of arbitrary commands as the limited user charx-oa. Charging could be interrupte…
-
High 7.1
File Upload vulnerability
A low-privileged remote attacker with "operator" access can upload arbitrary files via the REST endpoint intended for firmware updates, resulting in persistent storage of attacker-controlled files and potentially exhausting resources, which might lead to Deni…
-
High 7.8
udhcpc Privilege Escalation
A privilege escalation vulnerability in udhcpc allows a local user "charx-web" to execute arbitrary commands as root, resulting in full system compromise.
-
High 7.8
Local Privilege Escalation via Network scripts
A privilege escalation vulnerability in a script used for network configuration allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
-
High 8.6
Fallback to second RAUC slot with default credentials
An unauthenticated remote attacker can enforce the system to fall back to a firmware partition with an insecure configuration including default credentials. This could allow the attacker to gain SSH access to the system as an unprivileged user "user-app". Cha…
-
High 7.8
Local Privilege Escalation vulnerability in /etc/init.d/user-applications via user-application start script
A local privilege escalation vulnerability in the init-script for user-applications allows a low-privileged local user to execute arbitrary commands as root, resulting in full system compromise.
-
Critical 9.1
Missing input validation / stripping of CRLF characters in SystemConfigManager
An unauthenticated remote attacker can inject malicious input into the ModbusServer application because it does not validate the input it fetches from MQTT. This may lead to integrity and availability loss.
-
Critical 9.1
Creation of a new configuration by posting a malicious ID to MQTT
An unauthenticated remote attacker can post a malicious ID to the MQTT Broker results in the creation of a new configuration entry in the system configuration. This may lead to integrity and availability loss.
-
Critical 9.8
Missing authentication for MQTT Broker
Due to missing authentication, an unauthenticated remote attacker may access the MQTT broker, which is only protected from external access by a firewall. This may lead to the device being fully compromised.
-
High 7.1
Information tampering and Denial-of-service (DoS) vulnerability in CC-Link IE TSN communication protocol
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module,…
-
High 8.4
CWE-787 Out-of-bounds write vulnerability exists that could cause loss of data or potentially risk arbitrary code execu…
-
Critical 9.3
CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, …