    Philips Interventional Workstations

    Successful exploitation of this vulnerability makes it possible for someone within the hospital network to remotely shut down or restart the workstation. In the event the workstation is remotely shut down, physicians are still able to use diagnostic imaging f…

  • Medium

    Innokas Yhtymä Oy Vital Signs Monitor

    Successful exploitation of these vulnerabilities could allow an attacker to modify communications between downstream devices or cause some features of the affected devices to become disabled.

  • Medium max 6.3

    Schneider Electric Web Server on Modicon M340

    Successful exploitation of these vulnerabilities may allow write access and the execution of commands, which could result in data corruption or a web server crash.

  • Medium max 6.5
    ICSA-20-252-02 1 CVE rev. 4

    Siemens SIMATIC S7-300 and S7-400 CPUs (Update C)

    Successful exploitation of this vulnerability could result in credential disclosure.

    first Sep 8, 2020
  • Medium

    Siemens SIMATIC Controller Web Servers

    Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition.

  • Medium

    Mitsubishi Electric MELSEC iQ-R Series

    Successful exploitation of this vulnerability could cause a denial-of-service condition for the affected products.

  • Medium

    BD Alaris 8015 PC Unit and BD Alaris Systems Manager

    Successful exploitation of this vulnerability could lead to a drop in the wireless capability of the Alaris PC Unit. In order to exploit this vulnerability, an attacker would need to gain access to the network associated with the affected devices and redirect…

  • Medium

    NEXCOM NIO50

    Successful exploitation of these vulnerabilities could allow an attacker to view sensitive information and cause a denial-of-service condition due to improper input validation.

  • Medium

    Siemens Desigo Insight

  • Medium

    GE Reason S20 Ethernet Switch

    Successful exploitation of these vulnerabilities could allow unauthorized accounts manipulation and allow for remote code execution.

  • Medium max 6.8

    ICSMA-20-261-01_Philips Clinical Collaboration Platform

    Northridge Hospital Medical Center reported these vulnerabilities to Philips.

  • Medium

    Siemens Siveillance Video Client

  • Medium

    Tridium Niagara

    Successful exploitation of this vulnerability could result in a denial-of-service condition.

  • Medium max 4.3

    Trailer Power Line Communications

    The National Motor Freight Traffic Association (NMFTA) and Assured Information Security (AIS) have released research detailing a vulnerability within trailer Power Line Communications (PLC) signals. Their research indicates it is possible to read PLC signals …

  • Medium max 5.3

    Philips DreamMapper

    Successful exploitation of this vulnerability could allow an attacker access to the log file information containing descriptive error messages.

  • Medium
    ICSA-19-227-03 2 CVEs rev. 2

    Siemens SCALANCE Products (Update A)

    first Aug 13, 2019
  • Medium
    ICSA-19-318-02 1 CVE rev. 2

    Siemens S7-1200 and S7-200 SMART CPUs (Update B)

    first Nov 12, 2019
  • Medium

    Siemens SIMATIC HMI Panels

  • Medium max 6.8
    ICSA-20-170-01 1 CVE rev. 2

    Johnson Controls exacqVision (Update A)

    Successful exploitation of this vulnerability could allow an attacker with administrative privileges to potentially download and run a malicious executable that could allow the execution of operating system commands on the system.

    first Jun 18, 2020
  • Medium max 5.3
    ICSMA-20-170-06 1 CVE rev. 2

    BD Alaris PCU (Update A)

    Successful exploitation of this vulnerability could allow an attacker to cause a denial of service (DoS) on the target system and could cause the BD Alaris PCU to disconnect from the facility 's wireless network.

    first Jun 18, 2020
  • Medium

    Honeywell ControlEdge PLC and RTU

    Successful exploitation of these vulnerabilities could allow an attacker to obtain passwords and session tokens.

  • Medium

    BIOTRONIK CardioMessenger II

    Successful exploitation of these vulnerabilities could allow an attacker with physical access to the CardioMessenger to obtain sensitive data, obtain transmitted medical data from implanted cardiac devices with the implant 's serial number or impact Cardio Me…

  • Medium
    ICSMA-18-228-01 2 CVEs rev. 2

    Philips PageWriter TC10, TC20, TC30, TC50, and TC70 Cardiographs (Update A)

    Successful exploitation of these vulnerabilities could allow buffer overflows, or allow an attacker to access and modify settings on the device.

    first Aug 16, 2018
  • Medium

    LCDS LAquis SCADA

    Successful exploitation of these vulnerabilities could allow unauthorized attackers to view sensitive information and create files in arbitrary locations.

  • Medium

    GE Digital CIMPLICITY

    Successful exploitation of this vulnerability could allow an adversary to modify the systemwide CIMPLICITY configuration, leading to the arbitrary execution of code.

  • Medium

    HMS Networks eWON Flexy and Cosy

    Successful exploitation of this vulnerability could initiate a password change.

  • Medium max 4.3

    ICSA-20-098-05_KUKA.Sim Pro

    Federico Maggi of Trend Micro reported this vulnerability to CISA.

  • Medium

    Mitsubishi Electric MELSEC

    Successful exploitation of this vulnerability may render the device unresponsive.

  • Medium

    BD Pyxis MedStation and Pyxis Anesthesia (PAS) ES System

    The affected BD medical devices utilize a method of software application implementation called kiosk mode. This kiosk mode is vulnerable to local breakouts, which could allow an attacker with physical access to bypass kiosk mode and view and/or modify sensiti…

  • Medium

    Systech NDS-5000 Terminal Server

    Successful exploitation of this vulnerability could allow information disclosure, limit system availability, and may allow remote code execution.

  • Medium max 6.7

    Rockwell Automation Allen-Bradley Stratix 5950

    Successful exploitation of this vulnerability could allow an attacker to write a modified image to the component.

  • Medium
    ICSA-19-344-06 2 CVEs rev. 2

    Siemens SIMATIC S7-1200 and S7-1500 CPU Families (Update B)

    Successful exploitation of these vulnerabilities may allow an attacker to modify network traffic or impact the perceived integrity of the user program stored on the CPU.

    first Dec 10, 2019
  • Medium

    Siemens Spectrum Power 5

  • Medium

    Honeywell INNCOM INNControl 3

    Successful exploitation of this vulnerability could allow an attacker to escalate user privileges within the INNControl application.

  • Medium

    Siemens SIPORT MP

  • Medium

    Siemens OZW Web Server

  • Medium
    ICSA-18-058-01A 1 CVE rev. 3

    Siemens SIMATIC Industrial PCs (Update A)

    first Feb 22, 2018
  • Medium
    ICSA-18-282-05 1 CVE rev. 2

    Siemens SIMATIC S7-1500, SIMATIC S7-1500 Software Controller and SIMATIC ET 200SP OpenController (Update A)

    first Oct 9, 2018
  • Medium
    ICSA-18-317-03 1 CVE rev. 2

    Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal)

    first Nov 13, 2018
  • Medium
    ICSA-18-317-05 1 CVE rev. 3

    Siemens SIMATIC S7 (Update A)

    first Nov 13, 2018