4,108 results · Feed

  • Medium max 5.5

    Siemens SIMATIC PCS neo Administration Console

    The Administration Console of SIMATIC PCS neo leaks Windows admin credentials. An attacker with local Windows access to the Administration Console could get the credentials, and impersonate the admin user, thereby gaining admin access to other Windows systems…

  • High max 7.5

    Hitachi Energy Lumada APM Edge

    Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition or disclosure of sensitive information.

  • Medium max 5.9

    Fujitsu Software Infrastructure Manager

    Successful exploitation of this vulnerability could result in an attacker retrieving the password for the proxy server that is configured in ISM from the maintenance data.

  • High max 7.0
    ICSA-23-047-08 6 CVEs rev. 2

    Siemens RUGGEDCOM APE1808

    Insyde has published information on vulnerabilities in Insyde BIOS on November 8th 2022. These vulnerabilities also affect the RUGGEDCOM APE1808 product family. Siemens has released updates for the affected products and recommends to update to the latest vers…

    first Feb 14, 2023
  • High max 8.2
    ICSA-23-257-04 23 CVEs

    Siemens RUGGEDCOM APE1808 Products

    Insyde has published information on vulnerabilities in Insyde BIOS up to August 2023. These vulnerabilities also affect the RUGGEDCOM APE1808 product family. Siemens has released updates for the affected products and recommends to update to the latest version…

  • High max 7.8
    ICSA-23-157-01 3 CVEs rev. 2

    Delta Electronics CNCSoft-B DOPSoft

    Successful exploitation of these vulnerabilities could allow an attacker to exploit a buffer overflow condition and remotely execute arbitrary code.

    first Jun 6, 2023
  • Critical max 9.1

    Dover Fueling Solutions MAGLINK LX Console

    Successful exploitation of these vulnerabilities could allow an attacker to gain full access to the system.

  • Critical max 9.6

    Phoenix Contact TC ROUTER and TC CLOUD CLIENT

    Successful exploitation of this these vulnerabilities could execute code in the context of the user's browser or cause a denial of service.

  • Critical max 10.0

    Socomec MOD3GP-SY-120K

    Successful exploitation of these vulnerabilities could allow an attacker to execute malicious Javascript code, obtain sensitive information, or steal session cookies.

  • Medium

    Fujitsu Limited Real-time Video Transmission Gear "IP series"

    Successful exploitation of this vulnerability could result in an attacker logging into the web interface using the obtained credentials. The attacker could initialize or reboot the products, terminating the video transmission.

  • Critical max 9.8

    Softneta MedDream PACS Premium

    Successful exploitation of these vulnerabilities could allow an attacker to obtain and leak plaintext credentials or remotely execute arbitrary code.

  • Critical max 9.8

    ARDEREG Sistemas SCADA

    Successful exploitation of this vulnerability could allow an attacker to manipulate SQL query logic to extract sensitive information and perform unauthorized actions within the database.

  • High max 7.8

    GE Digital CIMPLICITY

    Successful exploitation of this vulnerability could allow a low-privileged local attacker to escalate privileges to SYSTEM.

  • Critical max 9.0

    Digi RealPort Protocol

    Successful exploitation of this vulnerability could allow the attacker to access connected equipment.

  • High max 8.8

    PTC Codebeamer

    Successful exploitation of this vulnerability could allow an attacker to inject arbitrary code into the target's browser.

    PTC
  • High max 7.5
    ICSA-23-236-01 1 CVE 1 exploited

    KNX Protocol

    Successful exploitation of this vulnerability could cause users to lose access to their device, potentially with no way to reset the device.

  • High max 8.6

    OPTO 22 SNAP PAC S1

    Successful exploitation of these vulnerabilities could allow an attacker to brute force passwords, access certain device files, or cause a denial-of-service condition.

  • High max 7.3

    CODESYS Development System

    Successful exploitation of this vulnerability could cause users to unknowingly launch a malicious binary placed by a local attacker.

  • Low max 3.3

    CODESYS Development System

    Successful exploitation of this vulnerability could provide a local attacker with account information.

  • Critical max 8.8

    CODESYS Development System

    Successful exploitation of this vulnerability could allow an attacker to execute a-man-in-the-middle attack to execute arbitrary code.

  • High max 9.8

    Rockwell Automation Select Distributed I/O Communication Modules

    Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service on the affected products.

  • High max 7.5
    ICSA-23-138-02 1 CVE rev. 2

    Mitsubishi Electric MELSEC WS Series

    Successful exploitation of this vulnerability could allow an attacker to bypass authentication and log in by connecting to the module via telnet to reset the module or, if certain conditions are met, either disclose or tamper with the module's configuration, …

    first May 18, 2023
  • Critical max 9.6

    Hitachi Energy AFF66x

    Successful exploitation of these vulnerabilities could allow an attacker to compromise availability, integrity, and confidentiality of the targeted devices.

  • Medium max 6.8

    Trane Thermostats

    Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands as root using a specially crafted filename.

  • Critical max 9.8

    Rockwell Automation ThinManager ThinServer

    Successful exploitation of these vulnerabilities could allow an attacker to remotely delete arbitrary files with system privileges.

  • Medium max 7.5

    ICONICS and Mitsubishi Electric Products

    Successful exploitation of these vulnerabilities could result in information disclosure, denial-of-service, or remote code execution.

  • High max 8.8

    Schneider Electric PowerLogic ION7400 / PM8000 / ION8650 / ION8800 / ION9000 Power Meters

    Successful exploitation of this vulnerability could allow an attacker to cause a disclosure of sensitive information, a denial of service, or modification of data if an attacker is able to intercept network traffic.

  • High max 8.6

    Rockwell Automation Armor PowerFlex

    Successful exploitation of this vulnerability could allow an attacker to send an influx of network commands, causing the product to generate an influx of event log traffic at a high rate, resulting in the stop of normal operation.

  • High max 7.5

    Hitachi Energy RTU500 series

    Successful exploitation of these vulnerabilities could cause a buffer overflow and reboot of the product.

  • High max 7.8
    ICSA-23-131-01 4 CVEs rev. 2

    Siemens Solid Edge

    Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as DWG, IFC, OBJ or STP format. If a user is tricked to open a malicious file with the affe…

    first May 9, 2023
  • High

    Siemens Parasolid Installer

    A vulnerability in Nullsoft Scriptable Installer System (NSIS) software (CVE-2023-37378) used in Parasolid installers before V36 creates an “uninstall directory” with insufficient access control. This could allow an attacker to misuse the vulnerability, and p…

  • High max 7.8

    Siemens Solid Edge SE2023

    Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as DFT, PAR or PSM format. If a user is tricked to open a malicious file with the affected …

  • Medium max 5.9

    Mitsubishi Electric GOT2000 and GOT SIMPLE

    Successful exploitation of this vulnerability could allow an attacker to hijack data connections or prevent legitimate users from establishing data connections.

  • High max 7.5

    Mitsubishi Electric GT and GOT Series Products

    Successful exploitation of this vulnerability could allow an attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords.

  • High max 7.5

    TEL-STER TelWin SCADA WebInterface

    Successful exploitation of this vulnerability could allow an unauthenticated attacker to read files on the system.

  • High max 7.1

    Sensormatic Electronics VideoEdge

    Successful exploitation of this vulnerability could allow a local user to edit the VideoEdge configuration file and interfere with VideoEdge operation.

  • Critical

    APSystems Altenergy Power Control

    Successful exploitation of this vulnerability may allow remote code execution.

  • High max 7.1

    ETIC Telecom RAS Authentication

    Successful exploitation of this vulnerability could allow an attacker to reconfigure the device or cause a denial-of-service condition.

  • High max 7.5

    PTC KEPServerEX

    Successful exploitation of this vulnerability could result in the affected device crashing.

    PTC
  • High max 7.1

    AXIS A1001

    Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code.