Skip to content
OpenAdvisories

Product · Automation Direct

CLICK PLC CPU Modules: C0-1x CPUs

5 known vulnerabilities.

CLICK PLC CPU Modules: C0-1x CPUs at a glance

Last 12 months
0
Critical · all time
3
Exploited · all time
0
Public exploit · all time
0
New vulnerabilities per month · last 12 months
0 1 1 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 0 vulnerabilities June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 0 vulnerabilities September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202600
Jul 202600
Jun 202600
May 202600
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202500
Aug 202500
Jul 202500
Jun 202500
May 202500
Apr 202500
Mar 202500
Feb 202500
Jan 202500
Dec 202400

5 results · Feed

  • High 7.5

    Automation Direct CLICK PLC CPU Modules Cleartext Transmission of Sensitive Information

    Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. An attacker who has network visibility can observe the password exchange.

  • Critical 9.8

    Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

    After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming con…

  • Critical 9.8

    Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

    All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can c…

  • High 7.5

    Automation Direct CLICK PLC CPU Modules Plaintext Storage of a Password

    The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs…

  • Critical 9.8

    Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

    Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active.