Skip to content
OpenAdvisories

Vendor

EG4 Electronics

4 known vulnerabilities.

EG4 Electronics at a glance

Last 12 months
0
Critical · all time
0
Exploited · all time
0
Public exploit · all time
0
New vulnerabilities per month · last 12 months
0 1 1 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 0 vulnerabilities June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 0 vulnerabilities September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202600
Jul 202600
Jun 202600
May 202600
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202500
Aug 202540
Jul 202500
Jun 202500
May 202500
Apr 202500
Mar 202500
Feb 202500
Jan 202500
Dec 202400

Latest advisories

  • High max 8.8
    ICSA-25-219-07 4 CVEs rev. 3

    EG4 Electronics EG4 Inverters (Update B)

    Successful exploitation of these vulnerabilities could allow an attacker to intercept and manipulate critical data, install malicious firmware, hijack device access, and gain unauthorized control over the system.

    first Aug 7, 2025

4 results · Feed

  • High 8.1

    EG4 Electronics EG4 Inverters Improper Restriction of Excessive Authentication Attempts

    The affected product does not limit the number of attempts for inputting the correct PIN for a registered product, which may allow an attacker to gain unauthorized access using brute-force methods if they possess a valid device serial number. The API provides…

  • Medium 5.8

    EG4 Electronics EG4 Inverters Observable Discrepancy

    The public-facing product registration endpoint server responds differently depending on whether the S/N is valid and unregistered, valid but already registered, or does not exist in the database. Combined with the fact that serial numbers are sequentially as…

  • High 8.8

    EG4 Electronics EG4 Inverters Download of Code Without Integrity Check

    The affected product allows firmware updates to be downloaded from EG4's website, transferred via USB dongles, or installed through EG4's Monitoring Center (remote, cloud-connected interface) or via a serial connection, and can install these files without int…

  • Medium 6.9

    EG4 Electronics EG4 Inverters Cleartext Transmission of Sensitive Information

    The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge crit…