ShineLan-X at a glance
- Last 12 months
- 7
- Critical · all time
- 4
- Exploited · all time
- 0
- Public exploit · all time
- 0
Show as table
| Month | Vulnerabilities | Critical |
|---|---|---|
| Nov 2026 | 0 | 0 |
| Oct 2026 | 0 | 0 |
| Sep 2026 | 0 | 0 |
| Aug 2026 | 0 | 0 |
| Jul 2026 | 0 | 0 |
| Jun 2026 | 0 | 0 |
| May 2026 | 0 | 0 |
| Apr 2026 | 0 | 0 |
| Mar 2026 | 0 | 0 |
| Feb 2026 | 0 | 0 |
| Jan 2026 | 0 | 0 |
| Dec 2025 | 7 | 4 |
| Nov 2025 | 0 | 0 |
| Oct 2025 | 0 | 0 |
| Sep 2025 | 0 | 0 |
| Aug 2025 | 0 | 0 |
| Jul 2025 | 0 | 0 |
| Jun 2025 | 0 | 0 |
| May 2025 | 0 | 0 |
| Apr 2025 | 0 | 0 |
| Mar 2025 | 0 | 0 |
| Feb 2025 | 0 | 0 |
| Jan 2025 | 0 | 0 |
| Dec 2024 | 0 | 0 |
Most common weaknesses
7 results · Feed
-
Critical 9.4
Undocumented backup Account and No Password Configuration Capability
Growatt ShineLan-X communication dongle has an undocumented backup account with undocumented credentials which allows significant level access to the device, such as allowing any attacker to access the Setting Center. This means that this is effectively backd…
-
Critical 9.4
Hardcoded FTP Credentials within the firmware
ShineLan-X contains a set of credentials for an FTP server was found within the firmware, allowing testers to establish an insecure FTP connection with the server. This may allow an attacker to replace legitimate files being deployed to devices with their own…
-
Critical 9.3
Authentication bypass on web interface
The authentication mechanism on web interface is not properly implemented. It is possible to bypass authentication checks by crafting a post request with new settings since there is no session token or authentication in place. This would allow an attacker for…
-
High 8.4
Stored Cross-Site Scripting (XSS) vulnerability in Growatt ShineLan-X
ShineLan-X contains a stored cross site scripting (XSS) vulnerability in the local configuration web server. The JavaScript code snippet can be inserted in the communication module’s settings center. This may allow attackers to force a legitimate user’s brows…
-
High 8.5
Stored cross site scripting (XSS) vulnerability in Growatt ShineLan-X
ShineLan-X contains a stored cross site scripting (XSS) vulnerability in the Plant Name field. A HTML payload will be displayed on the plant management page via a direct post. This may allow attackers to force a legitimate user’s browser’s JavaScript engine t…
-
High 8.6
SWD Interface Open on Growatt ShineLan-X
The SWD debug interface on the Growatt ShineLan-X communication dongle is available by default, allowing an attacker to attain debug access to the device and to extracting secrets or domains from within the device
-
Critical 9.4
Missing encryption on Local Configuration Interface or Cloud Endpoint Communication - Growatt MIC3300TL-X and ShineLan-X
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.