G520 Series at a glance
Show as table
| Month | Vulnerabilities | Critical |
|---|---|---|
| Nov 2026 | 0 | 0 |
| Oct 2026 | 0 | 0 |
| Sep 2026 | 2 | 0 |
| Aug 2026 | 0 | 0 |
| Jul 2026 | 0 | 0 |
| Jun 2026 | 0 | 0 |
| May 2026 | 0 | 0 |
| Apr 2026 | 0 | 0 |
| Mar 2026 | 4 | 1 |
| Feb 2026 | 0 | 0 |
| Jan 2026 | 0 | 0 |
| Dec 2025 | 0 | 0 |
| Nov 2025 | 0 | 0 |
| Oct 2025 | 0 | 0 |
| Sep 2025 | 0 | 0 |
| Aug 2025 | 0 | 0 |
| Jul 2025 | 0 | 0 |
| Jun 2025 | 0 | 0 |
| May 2025 | 0 | 0 |
| Apr 2025 | 0 | 0 |
| Mar 2025 | 0 | 0 |
| Feb 2025 | 0 | 0 |
| Jan 2025 | 0 | 0 |
| Dec 2024 | 0 | 0 |
Most common weaknesses
Latest advisories
-
Critical max 9.8
Lantronix EDS3000PS and EDS5000 (Update B)
Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and execute code with root-level privileges.
first Mar 10, 2026 -
High max 7.5ICSA-26-272-01 2 CVEs
Lantronix G520 Series Cellular Gateway
Successful exploitation of these vulnerabilities could allow an attacker to replace software and execute arbitrary code with root privileges.
6 results · Feed
-
High 7.5
Lantronix G520 Series Cellular Gateway Improper Verification of Cryptographic Signature
The device's update mechanism includes conditions that allow unauthorized software packages to be accepted as authentic. During the boot process, the stock done function disables signature verification in the OPKG configuration before restoring optional packa…
-
High 7.5
Lantronix G520 Series Cellular Gateway Cross-site Scripting
The device's update mechanism retrieves metadata for software updates over an unencrypted HTTP connection and stores portions of that metadata for later use. A management interface subsequently returns this stored value in a JSON response, and the web interfa…
-
High 7.2
Lantronix EDS5000, G520, and X300 OS Command Injection
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "name" parameter when deleting SSL credentials through the management interface. Injected commands are executed with root privileges.
-
High 7.2
Lantronix EDS5000, G520, and X300 OS Command Injection
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The Log Info page allows users to see log files by specifying their names. Due to a missing sanitization in the file name parameter, an authenticated attacker can inject arbitrary OS commands that are ex…
-
High 7.2
Lantronix EDS5000, G520, and X300 OS Command Injection
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "tunnel" parameter when killing a tunnel connection. Injected commands are executed with root privileges.
-
Critical 9.8
Lantronix EDS5000, G520, and X300 OS Command Injection
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authentication fails. The username is directly concatenated with the command without any sanitization. This allow attackers to injec…