Latest advisories
-
Medium max 5.2
Medtronic MyCareLink 24950 Patient Monitor (Update A)
Successful exploitation of these vulnerabilities may allow an attacker with physical access to obtain per-product credentials that are utilized to authenticate data uploads and encrypt data at rest. Additionally, an attacker with access to a set of these cred…
first Aug 7, 2018 -
Medium max 6.4ICSMA-18-179-01 2 CVEs
Medtronic MyCareLink Patient Monitor
If exploited, these vulnerabilities may allow privileged access to the monitor 's operating system. However, physical access to the MyCareLink monitor is required. Additionally, these vulnerabilities may allow a MyCareLink monitor, when operated within close …
4 results · Feed
-
Medium 4.4
Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload…
-
Medium 5.2
Medtronic MyCareLink Patient Monitor Network Credential Weakness
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.
-
Medium 6.2
Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physica…
-
Medium 6.4
Medtronic MyCareLink Patient Monitor Use of Hard-coded Password
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to t…