Skip to content
OpenAdvisories

Vendor

Mennekes

7 known vulnerabilities.

Mennekes at a glance

Last 12 months
2
Critical · all time
2
Exploited · all time
0
Public exploit · all time
0
New vulnerabilities per month · last 12 months
0 1 2 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 2 vulnerabilities, 2 critical June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 0 vulnerabilities September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202600
Jul 202600
Jun 202600
May 202622
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202500
Aug 202500
Jul 202500
Jun 202500
May 202500
Apr 202500
Mar 202550
Feb 202500
Jan 202500
Dec 202400

7 results · Feed

  • Critical 9.3

    Privilege Escalation

    The Mennekes Amtron series (firmware versions ≤ 5.22.3) is vulnerable to privilege escalation. An authenticated low-privileged user can change the passwords of the admin (operator) and manufacturer accounts via crafted POST requests.

  • Critical 9.3

    Authentication Bypass

    The Mennekes Amtron series (firmware versions ≤ 5.22.3) is vulnerable to an authentication bypass. An unauthenticated remote attacker can change the password of the user account via a crafted POST request to the /operator/operator endpoint.

  • High 7.1

    Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint

    The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.

  • High 8.7

    Mennekes smart/premium charges systems, Command injection in firmware upgrade

    The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.

  • Medium 5.3

    Mennekes smart/premium charges systems, SQL Injection in web configuration interface

    Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.

  • High 8.7

    Mennekes smart/premium charges systems, Command injection in sCU firmware update

    The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.

  • High 8.7

    Mennekes smart/premium charges systems, Command injection in time setting

    The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.