Skip to content
OpenAdvisories

Vendor

Philips

88 known vulnerabilities.

19 results · Clear filters · Feed

  • Medium 6.3

    Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability

    Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exp…

  • Medium 6.8

    Philips Vue PACS Use of Default Credentials

    The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system…

  • Medium 5.9

    Philips EncoreAnywhere Exposure of Sensitive Information to an Unauthorized Actor

    The HTTP header in Philips EncoreAnywhere contains data an attacker may be able to use to gain sensitive information.

  • Medium 6.5

    ICSMA-22-088-01 Philips e-Alert

    The software does not perform any authentication for critical system functionality.

  • Medium 6.5

    Philips Vue PACS Protection Mechanism Failure

    Philips Vue PACS versions 12.2.x.x and prior does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product.

  • Medium 6.1

    Philips Vue PACS

    Philips Vue PACS versions 12.2.x.x and prior does not ensure or incorrectly ensures structured messages or data are well formed and that certain security properties are met before being read from an upstream component or sent to a downstream component.

  • Medium 5.9

    Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of a Broken or Risky Cryptographic Algorithm

    The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series …

  • Medium 6.1

    Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of Hard-coded Cryptographic Key

    The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.

  • Medium 6.5

    Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation

    Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.

  • Medium 5.9

    Philips MRI 1.5T and 3T Incorrect Ownership Assignment

    Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

  • Medium 5.9

    Philips MRI 1.5T and 3T Information Exposure

    Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

  • Medium 5.9

    Philips MRI 1.5T and 3T Improper Access Control

    Philips MRI 1.5T and MRI 3T Version 5.3 through 5.8.1 does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

  • Medium 6.5

    Philips Interventional Workstations OS Command Injection

    Philips Interventional Workspot (Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5), Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live (Release 1.0), ViewForum (Release 6.3V1L10). The software constructs all or part of an OS command using externally influenced …

  • Medium 6.8

    Philips Clinical Collaboration Platform Configuration

    Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.

  • Medium 6.5

    Philips Clinical Collaboration Platform Algorithm Downgrade

    Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustio…

  • Medium 5.0

    Philips Clinical Collaboration Platform Protection Mechanism Failure

    When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct.

  • Medium 4.9

    Philips SureSigns VS4 Improper Authentication

    When an actor claims to have a given identity, Philips SureSigns VS4, A.07.107 and prior does not prove or insufficiently proves the claim is correct.

  • Medium 6.3

    Philips SureSigns VS4 Improper Access Control

    Philips SureSigns VS4, A.07.107 and prior does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

  • Medium 5.3

    Philips DreamMapper Insertion of Sensitive Information into Log File

    Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker.