Latest advisories
-
Medium
Philips Patient Monitoring Devices (Update C)
Successful exploitation of these vulnerabilities could result in unauthorized access, interrupted monitoring, and collection of access information and/or patient data. To successfully exploit these vulnerabilities, an attacker would need to gain either physic…
first Sep 10, 2020
7 results · Feed
-
Unscored —
Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kios…
-
Unscored —
Philips Patient Monitoring Devices Improper Validation of Syntactic Correctness of Input
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates t…
-
Unscored —
Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency
In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the applic…
-
Unscored —
Philips Patient Monitoring Devices Improper Check for Certificate Revocation
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly check…
-
Unscored —
Philips Patient Monitoring Devices Improper Authentication
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
-
Unscored —
Philips Patient Monitoring Devices Improper Neutralization of Formula Elements in a CSV File
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a com…
-
Unscored —
Philips Patient Monitoring Devices Cross-site Scripting
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploita…