Skip to content
OpenAdvisories

Product · Phoenix Contact

BPC 9102S

11 known vulnerabilities.

BPC 9102S at a glance

Last 12 months
5
Critical · all time
1
Exploited · all time
0
Public exploit · all time
0
New vulnerabilities per month · last 12 months
0 3 5 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 2 vulnerabilities June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 3 vulnerabilities, 1 critical September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202631
Jul 202600
Jun 202600
May 202620
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202500
Aug 202500
Jul 202540
Jun 202500
May 202500
Apr 202500
Mar 202500
Feb 202500
Jan 202500
Dec 202400

Latest advisories

  • High max 8.6
    VDE-2026-084 4 CVEs

    Phoenix Contact: CodeMeter Runtime Security Vulnerabilities in License Validation in the PLCnext Firmware

    This advisory addresses security vulnerabilities in Phoenix Contact products with an integrated CodeMeter Runtime, like PLCnext devices and Virtual Controls. These security vulnerabilities only may occur with versions <8.41a of the integrated software CodeMet…

  • Critical max 9.8
    VDE-2025-056 3 CVEs

    Phoenix Contact: Improper Input Validation Vulnerabilities in PLCnext Firmware

    This advisory addresses multiple security vulnerabilities in PLCnext firmware versions prior to 2026.0.3. The vulnerabilities may allow unauthenticated attackers to cause denial of service, trigger unexpected system behavior, or execute unauthorized SQL queri…

  • High max 8.8
    VDE-2026-050 2 CVEs

    Phoenix Contact: PLCnext Firmware Security Issues Related to APPs and Configuration Files

    This advisory addresses security issues in PLCnext firmware versions prior to 2026.0.3 that are related to APP handling and the processing of configuration files. The identified vulnerabilities affect APP installation authenticity as well as the handling of c…

  • High max 8.8
    VDE-2026-023 2 CVEs

    Phoenix Contact: Several products are affected by vulnerabilities found in OpenSSL

    Attacks are possible when installing key files and digitally signed objects. These attacks can only be carried out if these files are uploaded and installed by a logged-in user with high privileges.

  • Critical max 8.8
    VDE-2025-054 4 CVEs

    Phoenix Contact: Multiple Vulnerabilities in PLCnext Firmware

    Multiple vulnerabilities in the PLCnext system allowed low-privileged remote attackers to gain unauthorized access or trigger system reboots by manipulating configuration files and symbolic links. Affected services include watchdog, arp-preinit, and security-…

11 results · Feed

  • Medium 4.3

    SQL injection

    An authenticated attacker with low privileges can access an endpoint in the controller’s web interface that is vulnerable to SQL injection. The vulnerability affects a SQLite database used only for storing notification messages. Therefore, the impact is limit…

  • High 7.5

    Unauthenticated Denial of Service

    An unauthenticated denial-of-service vulnerability in the device's PLCnext Engineer communication interface allow an remote attacker to interrupt access via the client application. Successful exploitation prevents communication until the PLCnext service is ma…

  • Critical 9.8

    Unauthenticated Buffer Overflow in PROFINET Service

    The device's PROFINET service is affected by a buffer overflow vulnerability that exists in the default configuration. An unauthenticated remote attacker could exploit this vulnerability to reboot the device or execute arbitrary code.

  • High 8.8

    Insufficient Verification of Data Authenticity

    The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbi…

  • High 7.8

    Untrusted Search Path

    A local user with low privileges may be able to influence the behavior of a privileged system service by manipulating configuration or application-related files located in user-writable areas of the filesystem. The affected service processes data from locatio…

  • High 8.8

    Phoenix Contact: File access due to the replacement of a critical file used by the service security-profile

    A low privileged remote attacker with file access can replace a critical file or folder used by the service security-profile to get read, write and execute access to any file on the device.

  • High 8.8

    Phoenix Contact: File access due to the replacement of a critical file used by the arp-preinit script

    A low privileged remote attacker with file access can replace a critical file used by the arp-preinit script to get read, write and execute access to any file on the device.

  • High 8.8

    Phoenix Contact: File access due to the replacement of a critical file used by the watchdog

    A low privileged remote attacker with file access can replace a critical file used by the watchdog to get read, write and execute access to any file on the device after the watchdog has been initialized.

  • Medium 6.5

    Phoenix Contact: DoS of the PLC due to incorrect default permissions possible

    An low privileged remote attacker can enforce the watchdog of the affected devices to reboot the PLC due to incorrect default permissions of a config file.

  • Medium 6.5

    PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check

    A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.

  • High 8.8

    PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control

    A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices.