434 known vulnerabilities.
Products
434 results · Feed
-
Unscored —
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and P…
-
Unscored —
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and P…
-
Unscored —
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA An…
-
Unscored —
A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in whic…
-
Unscored —
A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute a…
-
Unscored —
An information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and pri…
-
Unscored —
Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerabi…
-
Unscored —
An improper access control vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and pr…
-
Unscored —
A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web serv…
-
Unscored —
An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prio…
-
Critical 9.8
Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run,…
-
Medium 6.5
Schneider Electric Modicon PLCs Predictable Value Range from Previous Values
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions pri…
-
Unscored —
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote…
-
Unscored —
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoM…
-
Unscored —
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corrupt…
-
High 7.5
Schneider Electric Device Type Managers (DTMs) Stack-based Buffer Overflow
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Commu…
-
Critical 10.0
Schneider Electric ETG3000 FactoryCast HMI Gateway Use of Hard-coded Credentials
The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.
-
Critical 10.0
Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct reque…
-
Critical 10.0
Schneider Electric Wonderware InTouch Access Anywhere Server Buffer Overflow
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.
-
Critical 10.0
Schneider Electric ProClima Command Injection
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clari…
-
Critical 10.0
Schneider Electric
Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, …
-
Medium 4.9
Schneider Electric SCADA Expert ClearSCADA Cross-site Scripting
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
-
Medium 6.4
Schneider Electric SCADA Expert ClearSCADA Improper Authentication
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
-
Medium 6.4
Schneider Electric SCADA Expert ClearSCADA Cryptographic Issues
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.
-
Medium 4.1
Schneider Electric VAMPSET Stack-based Buffer Overflow
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
-
High 7.8
Schneider Electric Wonderware Inadequate Encryption Strength
Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows remote attackers to obtain sensitive information by reading a credential file.
-
Low 2.1
Schneider Electric Wonderware Inadequate Encryption Strength
Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 uses weak encryption, which allows local users to obtain sensitive information by reading a credential file.
-
Low 2.1
Schneider Electric Wonderware Input Validation
Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to read arbitrary files or cause a denial of service via an XML external entity declaration in conjunction with an entity reference, related to an XML Ex…
-
High 7.5
Schneider Electric Wonderware Cross-site Scripting
Cross-site scripting (XSS) vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
-
High 7.5
Schneider Electric Wonderware SQL Injection
SQL injection vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
-
Medium 5.0
Schneider Electric OPC Factory Server Buffer Overflow
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDL…
-
Medium 6.8
Schneider Electric StruxureWare SCADA Expert ClearSCADA Improper Restriction of Operations within the Bounds of a Memory Buffer
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1…
-
Medium 5.9
Schneider Electric Floating License Manager Unquoted Search Path or Element
Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space cha…
-
Medium 6.8
Schneider Electric OFS Stack Buffer Overflow
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors i…