SCALANCE X307-2 EEC (2x 230V) at a glance
- Last 12 months
- 0
- Critical · all time
- 0
- Exploited · all time
- 0
- Public exploit · all time
- 0
Show as table
| Month | Vulnerabilities | Critical |
|---|---|---|
| Nov 2026 | 0 | 0 |
| Oct 2026 | 0 | 0 |
| Sep 2026 | 0 | 0 |
| Aug 2026 | 0 | 0 |
| Jul 2026 | 0 | 0 |
| Jun 2026 | 0 | 0 |
| May 2026 | 0 | 0 |
| Apr 2026 | 0 | 0 |
| Mar 2026 | 0 | 0 |
| Feb 2026 | 0 | 0 |
| Jan 2026 | 0 | 0 |
| Dec 2025 | 0 | 0 |
| Nov 2025 | 0 | 0 |
| Oct 2025 | 0 | 0 |
| Sep 2025 | 0 | 0 |
| Aug 2025 | 0 | 0 |
| Jul 2025 | 0 | 0 |
| Jun 2025 | 0 | 0 |
| May 2025 | 0 | 0 |
| Apr 2025 | 0 | 0 |
| Mar 2025 | 0 | 0 |
| Feb 2025 | 0 | 0 |
| Jan 2025 | 0 | 0 |
| Dec 2024 | 0 | 0 |
Latest advisories
-
Critical
Siemens SCALANCE X-300 Switches
Several SCALANCE X-300 switches contain multiple vulnerabilities. An unauthenticated attacker could reboot, cause denial of service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has relea…
first Apr 12, 2022 -
Medium
SSA-557804: Mirror Port Isolation Vulnerability in SCALANCE X Switches
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. Siemens has released updates for the affected products and recommends t…
first Mar 12, 2019 -
Medium
Siemens SCALANCE X (Update D)
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. Siemens has released updates for the affected products and recommends t…
first Mar 12, 2019 -
Critical
SSA-560465: DHCP Client Vulnerability in VxWorks-based Industrial Products
Various industry products are affected by a DHCP client vulnerability in Wind River VxWorks, that could allow an attacker to cause a heap-based buffer overflow. Siemens has released updates for several affected products and recommends to update to the latest …
first Jul 13, 2021 -
CriticalSSA-836527 9 CVEs
SSA-836527: Multiple Vulnerabilities in SCALANCE X-300 Switch Family Devices
Several SCALANCE X-300 switches contain multiple vulnerabilities. An unauthenticated attacker could reboot, cause denial of service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has relea…
12 results · Feed
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
Unscored —
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 …
-
High 7.5
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X…
-
Unscored —
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCAL…
-
Unscored —
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into …