SINAMICS GH150 at a glance
- Last 12 months
- 0
- Critical · all time
- 2
- Exploited · all time
- 0
- Public exploit · all time
- 0
Show as table
| Month | Vulnerabilities | Critical |
|---|---|---|
| Nov 2026 | 0 | 0 |
| Oct 2026 | 0 | 0 |
| Sep 2026 | 0 | 0 |
| Aug 2026 | 0 | 0 |
| Jul 2026 | 0 | 0 |
| Jun 2026 | 0 | 0 |
| May 2026 | 0 | 0 |
| Apr 2026 | 0 | 0 |
| Mar 2026 | 0 | 0 |
| Feb 2026 | 0 | 0 |
| Jan 2026 | 0 | 0 |
| Dec 2025 | 0 | 0 |
| Nov 2025 | 0 | 0 |
| Oct 2025 | 0 | 0 |
| Sep 2025 | 0 | 0 |
| Aug 2025 | 0 | 0 |
| Jul 2025 | 0 | 0 |
| Jun 2025 | 0 | 0 |
| May 2025 | 0 | 0 |
| Apr 2025 | 0 | 0 |
| Mar 2025 | 0 | 0 |
| Feb 2025 | 0 | 0 |
| Jan 2025 | 0 | 0 |
| Dec 2024 | 0 | 0 |
Latest advisories
-
Critical max 9.8
Siemens SINAMICS Medium Voltage Products Remote Access (Update B)
SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer …
first May 11, 2021 -
High max 9.8
SSA-752103: Telnet Authentication Vulnerability in SINAMICS Medium Voltage Products
SINAMICS medium voltage products, with telnet enabled on SIMATIC comfort HMI Panels, are affected by a remote access vulnerability that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default telnet is di…
first May 11, 2021 -
Critical max 9.8
SSA-286838: Multiple Vulnerabilities in SINAMICS Medium Voltage Products
SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer …
first May 11, 2021 -
High max 9.8
Siemens SINAMICS Medium Voltage Products Telnet (Update A)
Successful exploitation of this vulnerability could allow an attacker to gain full remote access to the HMI.
first May 11, 2021
5 results · Feed
-
High 7.5
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All v…
-
High 7.5
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All v…
-
High 7.5
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All v…
-
Critical 9.8
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All v…
-
Critical 9.8
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a…