High max 7.5SSA-400089 1 CVE
SSA-400089: Denial of Service Vulnerability in SIPROTEC 4 and SIPROTEC 4 Compact
SIPROTEC 4 and SIPROTEC 4 Compact devices contain a vulnerability that could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the lates…
-
High max 7.5ICSA-25-226-12 1 CVE
Siemens SIPROTEC 4 and SIPROTEC 4 Compact
SIPROTEC 4 and SIPROTEC 4 Compact devices contain a vulnerability that could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the lates…
-
High
Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module (Update D)
SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected p…
first Mar 8, 2018 -
CriticalSSA-617233 9 CVEs
SSA-617233: Urgent/11 TCP/IP Stack Vulnerabilities in SIPROTEC 4 7SJ66 Devices
SIPROTEC 4 7SJ66 devices are affected by multiple security vulnerabilities due to the underlying Wind River VxWorks network stack. This stack is affected by nine of the eleven vulnerabilities that are also known as "URGENT/11". The vulnerabilities could allow…
-
CriticalICSA-23-320-10 9 CVEs
Siemens SIPROTEC 4 7SJ66
SIPROTEC 4 7SJ66 devices are affected by multiple security vulnerabilities due to the underlying Wind River VxWorks network stack. This stack is affected by nine of the eleven vulnerabilities that are also known as "URGENT/11". The vulnerabilities could allow…
2 results · Feed
-
High 7.5
A vulnerability has been identified in SIPROTEC 4 6MD61 (All versions), SIPROTEC 4 6MD63 (All versions), SIPROTEC 4 6MD…
-
Unscored —
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions…