Skip to content
OpenAdvisories

Product · Siemens

SIPROTEC 4 7SJ66

2 known vulnerabilities.

SIPROTEC 4 7SJ66 at a glance

Last 12 months
0
Critical · all time
0
Exploited · all time
0
Public exploit · all time
0
New vulnerabilities per month · last 12 months
0 1 1 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 0 vulnerabilities June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 0 vulnerabilities September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202600
Jul 202600
Jun 202600
May 202600
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202500
Aug 202510
Jul 202500
Jun 202500
May 202500
Apr 202500
Mar 202500
Feb 202500
Jan 202500
Dec 202400

Latest advisories

  • High max 7.5
    SSA-400089 1 CVE

    SSA-400089: Denial of Service Vulnerability in SIPROTEC 4 and SIPROTEC 4 Compact

    SIPROTEC 4 and SIPROTEC 4 Compact devices contain a vulnerability that could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the lates…

  • High max 7.5

    Siemens SIPROTEC 4 and SIPROTEC 4 Compact

    SIPROTEC 4 and SIPROTEC 4 Compact devices contain a vulnerability that could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the lates…

  • High
    ICSA-18-067-01 2 CVEs rev. 7

    Siemens SIPROTEC 4, SIPROTEC Compact, DIGSI 4, and EN100 Ethernet Module (Update D)

    SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected p…

    first Mar 8, 2018
  • Critical
    SSA-617233 9 CVEs

    SSA-617233: Urgent/11 TCP/IP Stack Vulnerabilities in SIPROTEC 4 7SJ66 Devices

    SIPROTEC 4 7SJ66 devices are affected by multiple security vulnerabilities due to the underlying Wind River VxWorks network stack. This stack is affected by nine of the eleven vulnerabilities that are also known as "URGENT/11". The vulnerabilities could allow…

  • Critical

    Siemens SIPROTEC 4 7SJ66

    SIPROTEC 4 7SJ66 devices are affected by multiple security vulnerabilities due to the underlying Wind River VxWorks network stack. This stack is affected by nine of the eleven vulnerabilities that are also known as "URGENT/11". The vulnerabilities could allow…

2 results · Feed