| Month | Vulnerabilities | Critical |
|---|---|---|
| Nov 2026 | 0 | 0 |
| Oct 2026 | 0 | 0 |
| Sep 2026 | 3 | 0 |
| Aug 2026 | 0 | 0 |
| Jul 2026 | 2 | 1 |
| Jun 2026 | 0 | 0 |
| May 2026 | 0 | 0 |
| Apr 2026 | 0 | 0 |
| Mar 2026 | 0 | 0 |
| Feb 2026 | 0 | 0 |
| Jan 2026 | 0 | 0 |
| Dec 2025 | 0 | 0 |
| Nov 2025 | 0 | 0 |
| Oct 2025 | 0 | 0 |
| Sep 2025 | 0 | 0 |
| Aug 2025 | 0 | 0 |
| Jul 2025 | 0 | 0 |
| Jun 2025 | 0 | 0 |
| May 2025 | 0 | 0 |
| Apr 2025 | 0 | 0 |
| Mar 2025 | 0 | 0 |
| Feb 2025 | 0 | 0 |
| Jan 2025 | 0 | 0 |
| Dec 2024 | 0 | 0 |
Products
Latest advisories
-
High max 8.8ICSA-26-246-08 3 CVEs
Tycon Systems TPDIN-Monitor-WEB3
Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information.
-
Critical max 9.8
Tycon Systems TPDIN-Monitor-WEB2 (Update A)
Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk.
first Jul 21, 2026
5 results · Feed
-
High 8.1
Tycon Systems TPDIN-Monitor-WEB3 Missing Authorization
Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior are vulnerable to a Missing Authorization vulnerability. This could allow an attacker to extract system credentials, configurations, or flash contents.
-
High 8.8
Tycon Systems TPDIN-Monitor-WEB3 Cross-Site Request Forgery
Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior are vulnerable to a cross-site request forgery vulnerability. This could allow an attacker to perform state changing operations on the device.
-
Medium 6.5
Tycon Systems TPDIN-Monitor-WEB3 Use of Hard-coded Credentials
Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior are vulnerable to a use of hard-coded credential vulnerability. This could allow an attacker to intercept sensitive information or credentials.
-
Critical 9.8
Tycon Systems TPDIN-Monitor-WEB2 Missing Authentication for Critical Function
The Tycon Systems TPDIN-Monitor-WEB2 ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without requiring any…
-
Medium 4.3
Tycon Systems TPDIN-Monitor-WEB2 Cleartext Storage of Sensitive Information
The web management interface in Tycon Systems TPDIN-Monitor-WEB2 stores and displays system credentials in cleartext on a certain configuration page accessible to authenticated users. Any party with access to the administrative dashboard can immediately read …