Latest advisories
-
Critical max 9.1
WAGO: Multiple Vulnerabilities in CODESYS Runtime 2.3
Multiple vulnerabilities were reported in CODESYS 2.3 Runtime. The CODESYS 2.3 Runtime is an essential component in several WAGO PLC's.
first May 20, 2021 -
Critical max 9.1
WAGO: Multiple Vulnerabilities in CODESYS Runtime 2.3 and WebVisualisation
Multiple vulnerabilities were reported in CODESYS 2.3 Runtime. The CODESYS 2.3 Runtime is an essential component in several WAGO PLCs. All vulnerable PLCs are listed in chapter 'Affected Products'. https://www.codesys.com/security/security-reports.html
first Nov 16, 2021 -
High max 7.5
WAGO: PLC families 750-88x and 750-352 prone to DoS attack, versions < FW10 (Update A)
The Web-Based Management (WBM) of WAGOs programmable logic controller (PLC) is typically used for administration, commissioning and updates. Older firmware versions of the PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack. A…
first Oct 27, 2020 -
High max 8.2
WAGO: Vulnerability in web-based authentication in WAGO 750-8XX Version <= FW07
The Web-Based Management (WBM) of WAGOs programmable logic controller (PLC) is typically used for administration, commissioning and updates. With special crafted requests it is possible to change some special parameters without authentication.
first Sep 30, 2020 -
Medium max 4.9
WAGO: Controller with CODESYS 2.3 Runtime Denial-of-Service
An authenticated attacker can send a malformed packet to trigger a device crash via the CODESYS V2 runtime commands parsing. Update: 08.07.2024 release date of the updates has been changed.
first Jun 25, 2023
4 results · Feed
-
Medium 4.9
WAGO: DoS in multiple products in multiple versions using Codesys
Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a specifically crafted packet to the CODESYS V2 runtime.
-
Medium 4.9
WAGO: DoS in multiple versions of multiple products
Multiple WAGO devices in multiple versions may allow an authenticated remote attacker with high privileges to DoS the device by sending a malformed packet.
-
High 7.5
WAGO: PLC families 750-88x and 750-352 prone to DoS attack
Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.
-
High 8.2
WAGO: Vulnerability in web-based authentication in WAGO 750-8XX Version <= FW07