Description
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code.
Affected products
| Vendor | Product | Affected | Fixed |
|---|---|---|---|
| Delta Electronics | InfraSuite Device Master | < 1.0.5 | 1.0.5 |
Public exploits
Exploit or proof-of-concept code for this vulnerability is publicly available, which lowers the bar for attackers. Treat it as a reason to patch sooner.
Metasploit 1 module
-
Delta Electronics InfraSuite Device Master Deserialization
exploit/windows/misc/delta_electronics_infrasuite_deserialization
Sources: PoC-in-GitHub, Metasploit Framework, Exploit-DB — updated daily. Only links are listed; no exploit code is hosted here.
Advisories 1
- ICSA-23-080-02 Delta Electronics InfraSuite Device Master CISA ICS & IT advisories · Mar 29, 2023