Lack of cryptographic protection in Wertheim SafeController 5400 enables RS-485 message sniffing and replay

Published Jun 15, 2026 · Updated Jun 15, 2026 · Assigned by SEC-VLab

Description

The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.

Affected products

VendorProductAffectedFixed
Wertheim Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320 —