Week 4, 2013
21–27 January 2013
Newly exploited 0
Added to CISA KEV or flagged as exploited by ENISA this week — patch these first.
No newly exploited vulnerabilities were reported this week.
Critical new vulnerabilities
Published this week with a CVSS score of 9.0 or higher, most likely to be exploited first.
-
Critical 9.8
CVE-2012-6437 Rockwell Automation ControlLogix PLC Improper AuthenticationEPSS 11%
Rockwell Automation · CompactLogix and SoftLogix controllers · MicroLogix · 1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules
-
Critical 9.8
CVE-2012-6068 3S CoDeSys Improper Access ControlEPSS 5.3%
Festo · 3S-Smart Software Solutions · CECX-X-M1 Modular Controller with CoDeSys and SoftMotion · CECX-X-C1 Modular Master Controller with CoDeSys
-
Critical 10.0
CVE-2012-6069 3S CoDeSys Relative Path TraversalEPSS 2.6%
Festo · 3S-Smart Software Solutions · CECX-X-C1 Modular Master Controller with CoDeSys · CECX-X-M1 Modular Controller with CoDeSys and SoftMotion
Not critical, but likely targeted
New this week with the highest EPSS — a lower CVSS score does not mean nobody will use them.
-
Unscored
CVE-2012-6096 Multiple stack-based buffer overflows in the get_history function in history.cgi in Nagios Core before 3.4.4, and Icinga 1.6.x before 1.6.2, 1.7.x before 1.7.4…EPSS 66%
-
Medium 5.0
CVE-2012-6441 Rockwell Automation ControlLogix PLC Information ExposureEPSS 57%
Rockwell Automation · ControlLogix, CompactLogix, GuardLogix, and SoftLogix · ControlLogix and GuardLogix controllers · CompactLogix L32E and L35E controllers
-
Unscored
CVE-2013-0209 lib/MT/Upgrade.pm in mt-upgrade.cgi in Movable Type 4.2x and 4.3x through 4.38 does not require authentication for requests to database-migration functions, wh…EPSS 45%
-
High 7.5
CVE-2012-6435 Rockwell Automation ControlLogix PLC Improper Access ControlEPSS 43%
Rockwell Automation · CompactLogix L32E and L35E controllers · 1794-AENTR FLEX I/O EtherNet/IP adapter · CompactLogix and SoftLogix controllers
-
High 7.5
CVE-2012-6438 Rockwell Automation ControlLogix PLC Improper Input ValidationEPSS 36%
Rockwell Automation · MicroLogix · 1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules · 1788-ENBT FLEXLogix adapter
-
High 7.5
CVE-2012-6442 Rockwell Automation ControlLogix PLC Improper Access ControlEPSS 35%
Rockwell Automation · 1788-ENBT FLEXLogix adapter · ControlLogix, CompactLogix, GuardLogix, and SoftLogix · ControlLogix and GuardLogix controllers
-
High 7.5
CVE-2012-6436 Rockwell Automation ControlLogix PLC Improper Input ValidationEPSS 35%
Rockwell Automation · CompactLogix and SoftLogix controllers · MicroLogix · 1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules
-
Unscored
CVE-2013-0928 The NetWorker command processor in rrobotd.exe in the Device Manager in EMC AlphaStor 4.0 before build 800 allows remote attackers to execute arbitrary command…EPSS 34%
Advisories
- ICSA-13-113-01 Wonderware Information Server Vulnerabilities 4 CVEs