Critical 9.1
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exist…
-
Critical 9.1
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could…
-
Critical 10.0
Rockwell Automation FactoryTalk AssetCentre OS Command Injection
A vulnerability exists in the SaveConfigFile function of the RACompare Service, which may allow for OS command injection. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in Rockwell Automation FactoryTalk AssetCen…
-
Critical 10.0
Rockwell Automation FactoryTalk AssetCentre Deserialization of Untrusted Data
A deserialization vulnerability exists in how the LogService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands …
-
Critical 10.0
Rockwell Automation FactoryTalk AssetCentre Deserialization of Untrusted Data
A deserialization vulnerability exists in how the ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary comma…
-
Critical 10.0
Rockwell Automation FactoryTalk AssetCentre Use of Potentially Dangerous Function
Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier does not properly restrict all functions relating to IIS remoting services. This vulnerability may allow a remote, unauthenticated attacker to modify sensitive data in FactoryTalk AssetCentre.
-
Critical 10.0
Rockwell Automation FactoryTalk AssetCentre SQL Injection
The AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier exposes functions lacking proper authentication. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary SQL statements.
-
Critical 10.0
Rockwell Automation FactoryTalk AssetCentre SQL Injection
A vulnerability exists in the RunSearch function of SearchService service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier, which may allow for the execution of remote unauthenticated arbitrary SQL statements.
-
Critical 10.0
Rockwell Automation FactoryTalk AssetCentre SQL Injection
The ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier exposes functions lacking proper authentication. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary SQL statements.
-
Critical 10.0
Rockwell Automation FactoryTalk AssetCentre Deserialization of Untrusted Data
A deserialization vulnerability exists in how the AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands …
-
Critical 10.0CVE-2021-27460 Public exploit
Rockwell Automation FactoryTalk AssetCentre Deserialization of Untrusted Data
Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier components contain .NET remoting endpoints that deserialize untrusted data without sufficiently verifying that the resulting data will be valid. This vulnerability may allow a remote, unauthentica…
-
Critical 9.1
Rockwell Automation ISaGRAF5 Runtime Relative Path Traversal
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is po…
-
Critical 9.6
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i8…
-
Critical 9.8
ICSA-21-357-01 Moxa MGate Protocol Gateways
The affected products contain vulnerable firmware, which could allow an attacker to sniff the traffic and decrypt login credential details. This could give an attacker admin rights through the HTTP web server.
-
Critical 9.8
OmniCore RobotWare Missing Authentication Vulnerability
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port.
-
Critical 9.0
Weak default credential associated with TCP port 26
Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi En…
-
Critical 9.9
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 U…
-
Critical 9.1
CODESYS V2 web server: crafted requests could trigger a buffer over-read (DoS)
Crafted web server requests can be utilised to read partial stack or heap memory or may trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22.
-
Critical 9.1
Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC …
-
Critical 9.8
Moxa MXview Network Management Software
A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries.
-
Critical 10.0CVE-2021-38454 EPSS 16%
Moxa MXview Network Management Software
A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries.
-
Critical 9.8
Moxa MXview Network Management Software
A use of hard-coded password vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to gain access through accounts using default passwords
-
Critical 9.8
A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Et…
-
Critical 9.8
ABB Base Software for SoftControl Remote Code Execution vulnerability
A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
-
Critical 9.8
WAGO: Authentication Vulnerability in Web-Based Management
This vulnerability allows an attacker who has access to the WBM to read and write settings-parameters of the device by sending specifically constructed requests without authentication on multiple WAGO PLCs in firmware versions up to FW07.
-
Critical 9.8
In WirelessHART-Gateway versions 3.0.7 to 3.0.9 hard-coded credentials have been found
In PEPPERL+FUCHS WirelessHART-Gateway 3.0.7 to 3.0.9 the SSH and telnet services are active with hard-coded credentials.
-
Critical 9.8
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open C…
-
Critical 9.1
WAGO: PFC200 Access to files outside the home directory
On WAGO PFC200 devices in different firmware versions with special crafted packets an authorised attacker with network access to the device can access the file system with higher privileges.
-
Critical 10.0
WAGO: Managed Switches: Unauthorized creation of user accounts
In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users.
-
Critical 9.8
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All v…
-
Critical 9.8
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a…
-
Critical 9.8
MOXA NPort IAW5000A-I/O Series
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication.
-
Critical 9.8
MOXA NPort IAW5000A-I/O Series
The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords.
-
Critical 9.8
Weak Authentication in Symphony Plus
In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process.
-
Critical 9.8
SQL Injection in Symphony Plus
In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of…
-
Critical 9.8
Authentication Bypass in Symphony Plus
The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application …
-
Critical 10.0
Command Injection Vulnerability in I/O-Check Service of WAGO PFC100, PFC200 and Touch Panel 600 Series with firmware versions <=FW10
The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx…
-
Critical 9.1
WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Versions <= FW03
Improper Authentication vulnerability in WAGO 750-8XX series with FW version <= FW03 allows an attacker to change the settings of the devices by sending specifically constructed requests without authentication This issue affects: WAGO 750-362, WAGO 750-363, W…
-
Critical 9.8
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < …
-
Critical 9.0
Rockwell Automation FactoryTalk View SE
All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell …