Critical 9.1
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page…
-
Critical 9.1
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V5.0). The affected application does not properl…
-
Critical 9.1
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versi…
-
Critical 9.3
Information Disclosure, Tampering, and Denial-of-Service Vulnerabilities in GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, AnalytiX, GENESIS, and MC Works64
Cleartext Storage of Sensitive Information in GUI vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Ele…
-
Critical 9.3
Information Disclosure, Tampering, and Denial-of-Service Vulnerabilities in GENESIS64, ICONICS Suite, MobileHMI, Hyper Historian, AnalytiX, GENESIS, and MC Works64
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric H…
-
Critical 10.0
Hidden CLI Function Allows Root Access
An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device.
-
Critical 10.0CVE-2026-3611 Public exploit
Honeywell IQ4x BMS Controller Missing authentication for critical function
The Honeywell IQ4x building management controller, exposes its full web-based HMI without authentication in its factory-default configuration. With no user module configured, security is disabled by design and the system operates under a System Guest (level 1…
-
Critical 9.6
Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through …
-
Critical 9.8
Honeywell CCTV Products Missing Authentication for Critical Function
The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the "forgot password" recovery email address.
-
Critical 9.8
Hardcoded Key Allows Credential Disclosure
User credentials are stored using AES‑ECB encryption with a hardcoded key. An unauthenticated remote attacker obtaining the configuration file can decrypt and recover plaintext usernames and passwords, especially when combined with the authentication bypass.
-
Critical 9.8
Stack Overflow via Oversized Cookie Fields in lighttpd
Improper length handling when parsing multiple cookie fields (including TRACKID) allows an unauthenticated remote attacker to send oversized cookie values and trigger a stack buffer overflow, resulting in a denial‑of‑service condition and possible remote code…
-
Critical 9.8
Stack Overflow via SESSIONID Cookie in lighttpd
An unauthenticated remote attacker can send a crafted HTTP request containing an overly long SESSIONID cookie. This can trigger a stack buffer overflow in the modified lighttpd server, causing it to crash and potentially enabling remote code execution due to …
-
Critical 9.8
DIAView - Authentication Bypass Vulnerability
Delta Electronics DIAView has multiple vulnerabilities.
-
Critical 9.8
WAGO 750-8212 PFC200 G2 2ETH RS Privilege Escalation
WAGO 750-8212 PFC200 G2 2ETH RS firmware contains a privilege escalation vulnerability that allows attackers to manipulate user session cookies. Attackers can modify the cookie's 'name' and 'roles' parameters to elevate from ordinary user to administrative pr…
-
Critical 10.0
Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauth…
-
Critical 9.1
DVP-12SE11T - Out-of-bound memory write Vulnerability
DVP-12SE11T - Out-of-bound memory write Vulnerability
-
Critical 9.1
DVP-12SE11T - Password Protection Bypass
DVP-12SE11T - Password Protection Bypass
-
Critical 9.8
Stack-based buffer overflow via unsafe sscanf in check_cookie()
An unauthenticated remote attacker can abuse unsafe sscanf calls within the check_cookie() function to write arbitrary data into fixed-size stack buffers which leads to full device compromise.
-
Critical 9.8
Stack-based buffer overflow via unsafe sscanf in check_account()
An unauthenticated remote attacker can abuse unsafe sscanf calls within the check_account() function to write arbitrary data into fixed-size stack buffers which leads to full device compromise.
-
Critical 9.6
ABB Ability Edgenius Authentication Bypass
Authentication Bypass Using an Alternate Path or Channel vulnerability in ABB ABB Ability Edgenius.This issue affects ABB Ability Edgenius: 3.2.0.0, 3.2.1.1.
-
Critical 9.3
Smallworld SWMFS Improper Authentication
Improper Authentication vulnerability in GE Vernova Smallworld on Windows, Linux allows Authentication Abuse.This issue affects Smallworld: 5.3.3 and prior versions for Linux, and 5.3.4. and prior versions for Windows.
-
Critical 10.0
Missing Authentication Vulnerability
Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects . All firmware versions with the Serial Number from 2000 to 5166
-
Critical 9.9
An Use of Hard-coded Credentials vulnerability has been identified in Moxa’s network security appliances and routers. T…
-
Critical 9.3
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and ro…
-
Critical 9.3
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and ro…
-
Critical 9.9
Rockwell Automation Comms - 1783-NATR Multiple Broken Authentication Vulnerabilities
Multiple Broken Authentication security issues exist in the affected product. The security issues are due to missing authentication checks on critical functions. These could result in potential denial-of-service, admin account takeover, or NAT rule modificati…
-
Critical 9.8
A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 15…
-
Critical 9.8
A vulnerability has been identified in TeleControl Server Basic V3.1 (All versions >= V3.1.2.2 < V3.1.2.3). The affecte…
-
Critical 9.8
Missing Authentication for Database Access in Web Application
The database for the web application is exposed without authentication, allowing an unauthenticated remote attacker to gain unauthorized access and potentially compromise it.
-
Critical 10.0
DIALink - Directory Traversal Authentication Bypass Vulnerability
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
-
Critical 9.1
A vulnerability has been identified in SIMATIC Virtualization as a Service (SIVaaS) (All versions). The affected applic…
-
Critical 9.8
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATI…
-
Critical 9.8
Mitsubishi Electric Europe smartRTU OS Command Injection
A remote unauthenticated attacker who has bypassed authentication could execute arbitrary OS commands to disclose, tamper with, destroy or delete information in Mitsubishi Electric smartRTU, or cause a denial-of service condition on the product.
-
Critical 9.3
Rockwell Automation Micro800 Vulnerability
A security issue exists due to improper handling of malformed CIP Forward Close packets during fuzzing. The controller enters a solid red Fault LED state and becomes unresponsive. Upon power cycle, the controller will enter recoverable fault where the MS LED …
-
Critical 9.3
Rockwell Automation ControlLogix® Ethernet Remote Code Execution Vulnerability
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and …
-
Critical 9.1
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.2). Affected products do not pr…
-
Critical 9.8
Unauthenticated RCE
Due to an issue in configuration, code that was intended for debugging purposes was included in the market release of the ASPECT FW allowing an attacker to bypass authentication. This vulnerability may allow an attacker to change the system time, access files…
-
Critical 9.3CVE-2025-53417 EPSS 20%
File Parsing Deserialization of Untrusted Data in DTM Soft
DIAView (v4.2.0 and prior) - Directory Traversal Information Disclosure Vulnerability
-
Critical 9.5CVE-2025-50121 EPSS 22%
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exis…
-
Critical 9.4
Lack of buffer clearing before reuse may result in incorrect system behavior.
The Honeywell Experion PKS and OneWireless WDM contains an Integer Underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which could resul…