1,185 results · Clear filters · Feed
-
Critical max 9.8
Dataprobe iBoot-PDU
This updated advisory is a follow-up to the original advisory titled ICSA-22-263-03 Dataprobe iBoot-PDU that was published September 20, 2022, on the ICS webpage on cisa.gov/ICS.
first Sep 20, 2022 -
Critical max 10.0ICSMA-23-117-01 2 CVEs
Illumina Universal Copy Service
Successful exploitation of these vulnerabilities could allow an attacker to take any action at the operating system level. A threat actor could impact settings, configurations, software, or data on the affected product; a threat actor could interact through t…
-
Critical max 10.0ICSA-23-110-01 1 CVE
INEA ME RTU
Successful exploitation of this vulnerability could allow remote code execution.
-
Critical max 9.9
Siemens SIMATIC WinCC (Update E)
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to …
first Nov 9, 2021 -
Critical max 9.8ICSA-23-103-07 1 CVE
Siemens CPCI85 Firmware of SICAM A8000 Devices
The CPCI85 firmware of SICAM A8000 CP-8031 and CP-8050 is affected by unauthenticated command injection vulnerability. This could allow an attacker to perfom remote code execution. Siemens has released updates for the affected products and recommends to updat…
-
Critical max 8.8ICSA-23-096-06 5 CVEs
mySCADA myPRO
Successful exploitation of this vulnerability could allow an authenticated user to inject arbitrary operating system commands.
-
CriticalICSA-23-096-01 1 CVE
Industrial Control Links ScadaFlex II SCADA Controllers
Successful exploitation of this vulnerability could allow an authenticated attacker to overwrite, delete, or create files.
-
Critical max 9.9ICSA-23-096-05 5 CVEs
Hitachi Energy MicroSCADA System Data Manager SDM600
Successful exploitation of these vulnerabilities could allow an attacker to take remote control of the product.
-
Critical max 9.3ICSA-23-094-01 5 CVEs
Nexx Smart Home Device
Successful exploitation of these vulnerabilities could allow an attacker to receive sensitive information, execute application programmable interface (API) requests, or hijack devices.
-
Critical max 6.9ICSA-23-075-06 3 CVEs
Honeywell OneWireless Wireless Device Manager
Successful exploitation of these vulnerabilities could disclose sensitive information, allow privilege escalation, or allow remote code execution.
-
Critical max 9.8
AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere
This updated advisory is a follow-up to the original advisory titled ICSA-22-342-02 AVEVA InTouch Access Anywhere, published December 8, 2022 on the ICS webpage at cisa.gov/topics/industrial-control-systems.
first Dec 8, 2022 -
Critical max 9.8ICSA-23-080-06 3 CVEs
Rockwell Automation ThinManager
Successful exploitation of these vulnerabilities could allow an attacker to potentially perform remote code execution on the target or crash the software.
-
Critical max 9.1ICSA-23-073-01 1 CVE
Omron CJ1M PLC
Successful exploitation of these vulnerabilities could allow an attacker to bypass user memory protections by writing to a specific memory address. An attacker can also overwrite passwords and lock engineers from reading their own memory regions.
-
Critical max 9.8ICSA-23-068-01 13 CVEs
Akuvox E11
Successful exploitation of these vulnerabilities could cause loss of sensitive information, unauthorized access, and grant full administrative control to an attacker.
-
Critical max 9.8ICSA-23-073-04 1 CVE
AVEVA Plant SCADA and AVEVA Telemetry Server
Successful exploitation of this vulnerability could allow an unauthenticated user to read data, cause a denial of service, and tamper with alarm states.
-
Critical max 9.8ICSA-23-080-02 13 CVEs
Delta Electronics InfraSuite Device Master
Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to obtain access to files and credentials, escalate privileges, and remotely execute arbitrary code.
-
Critical max 7.5
Siemens Industrial Products LLDP (Update D)
There are multiple vulnerabilities in an underlying Link Layer Discovery Protocol (LLDP) third party library. Siemens has released updates for the affected products and recommends to update to the latest versions.
first Jul 13, 2021 -
Critical max 10.0
Siemens SRCS VPN Feature in SIMATIC CP Devices
The below referenced devices contain multiple vulnerabilities that could be exploited when the SINEMA Remote Connect Server (SRCS) VPN feature is used. The feature is not activated by default. The most severe could allow an attacker to execute arbitrary code …
first Jul 12, 2022 -
Critical max 9.8
Siemens SCALANCE, RUGGEDCOM Third-Party
Multiple third-party component vulnerabilities were reported for the Busybox applet, the Linux Kernel, OpenSSL, OpenVPN and various other components used by the RUGGEDCOM and SCALANCE products. The vulnerabilities range from improper neutralization of special…
-
Critical max 8.1ICSA-23-061-02 1 CVE
Baicells Nova
Successful exploitation of this vulnerability could allow commands performed using pre-login execution and with root permissions.
-
Critical max 5.5ICSA-23-052-01 2 CVEs
Mitsubishi Electric MELSOFT iQ AppPortal
Successful exploitation of these vulnerabilities could allow a malicious attacker to make unidentified impacts such as authentication bypass, information disclosure, denial-of-service, or bypass IP address authentication.
-
Critical max 9.8ICSA-23-054-01 2 CVEs
PTC ThingWorx Edge
Successful exploitation of these vulnerabilities could allow an attacker to crash the device they accessed or could allow remote code execution.
-
Critical max 9.3ICSA-23-045-01 1 CVE
Weintek EasyBuilder Pro cMT Series
Successful exploitation of this vulnerability could allow an attacker to gain control of the user's machine or gain sensitive information.
-
Critical max 9.3
Siemens SINUMERIK ONE and SINUMERIK MC
SINUMERIK ONE and SINUMERIK MC products are affected by a weak key protection vulnerability in the integrated S7-1500 CPU. The weak key protection vulnerability in the integrated S7-1500 CPU is documented in more detail in SSA-568427 [1]. Siemens has released…
first Nov 8, 2022 -
Critical
Siemens SCALANCE W1750D
The SCALANCE W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to denial of service, unauthenticated remote code execution or stored XSS. Siemens has rel…
first Nov 8, 2022 -
Critical max 9.8ICSA-23-047-03 4 CVEs
Siemens Brownfield Connectivity Client
Siemens has released a new version for Brownfield Connectivity - Client that contains fixes for multiple vulnerabilities in the underlying OpenSSL library. Successful exploitation of these vulnerabilities could lead to Denial of Service (DoS). Siemens has rel…
-
Critical max 10.0ICSA-23-047-10 1 CVE
Siemens COMOS
COMOS is affected by memory corruption vulnerability in the cache validation service that could allow an attacker to execute arbitrary code or cause denial of service condition. Siemens has released updates for the affected products and recommends to update t…
-
Critical max 9.1ICSA-23-040-01 2 CVEs
Control By Web X-400, X-600M
Successful exploitation of these vulnerabilities could allow an attacker to inject malicious JavaScript and execute arbitrary code remotely, which could result in a loss of sensitive information.
-
Critical max 9.8ICSA-23-040-02 7 CVEs
LS ELECTRIC XBC-DN32U
Successful exploitation of these vulnerabilities could allow an attacker to steal Programmable Logic Controller (PLC) information, cause users to lose communication with the PLC, modify PLC code, obtain credentials, and create a denial-of-service condition.
-
Critical max 8.1ICSA-23-033-03 1 CVE
Baicells Nova
Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands.
-
Critical max 9.8
Mitsubishi Electric Multiple Factory Automation Products (Update B)
Successful exploitation of these vulnerabilities could create a denial-of-service condition or enable arbitrary code execution.
first Aug 30, 2022 -
Critical max 8.8ICSA-23-033-04 1 CVE
Delta Electronics DVW-W02W2-E2
Successful exploitation of this vulnerability could allow a threat actor with low privileges to gain root access to the device, which could then allow them to send malicious commands to managed devices.
-
Critical max 9.0ICSA-23-033-05 2 CVEs
Delta Electronics DX-2100-L1-CN
Successful exploitation of these vulnerabilities could allow an attacker with low privileges to gain root access or allow an unauthenticated attacker to perform remote code execution.
-
Critical max 9.8ICSA-23-026-06 2 CVEs
Rockwell Automation products using GoAhead Web Server
Successful exploitation of these vulnerabilities could have a high impact on the confidentiality, integrity, and availability of the vulnerable devices.
-
Critical max 9.8
Contec CONPROSYS HMI System (CHS)
Successful exploitation of these vulnerabilities could allow a remote attacker to send specially crafted requests and cause a loss of sensitive information.
first Dec 13, 2022 -
Critical max 9.8
Delta Electronics InfraSuite Device Master
Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to remotely execute code, cause a denial-of-service condition by remotely deleting files or changing group privileges, or remotely read and write files, all with local ad…
first Oct 25, 2022 -
Critical max 9.8ICSA-23-017-01 5 CVEs
GE Digital Proficy Historian
Successful exploitation of these vulnerabilities could crash the device after access, cause a buffer overflow condition, and allow remote code execution.
-
Critical max 10.0ICSA-23-012-01 9 CVEs
Sewio RTLS Studio
Successful exploitation of these vulnerabilities could allow an attacker to obtain unauthorized access to the server, alter information, create a denial-of-service condition, gain escalated privileges, and execute arbitrary code.
-
Critical max 10.0ICSA-23-012-03 5 CVEs
InHand Networks InRouter
Successful exploitation of these vulnerabilities could allow a message queuing telemetry transport (MQTT) command injection, unauthorized disclosure of sensitive device information, and remote code execution. If properly chained, these vulnerabilities could r…
-
Critical max 9.8ICSA-23-012-05 2 CVEs
SAUTER Controls Nova 200 - 220 Series (PLC 6)
Successful exploitation of these vulnerabilities could allow unauthorized visibility to sensitive information and remote code execution.