  • Critical max 9.8
    ICSA-22-263-03 12 CVEs rev. 2

    Dataprobe iBoot-PDU

    This updated advisory is a follow-up to the original advisory titled ICSA-22-263-03 Dataprobe iBoot-PDU that was published September 20, 2022, on the ICS webpage on cisa.gov/ICS.

    first Sep 20, 2022
  • Critical max 10.0

    Illumina Universal Copy Service

    Successful exploitation of these vulnerabilities could allow an attacker to take any action at the operating system level. A threat actor could impact settings, configurations, software, or data on the affected product; a threat actor could interact through t…

  • Critical max 10.0

    INEA ME RTU

    Successful exploitation of this vulnerability could allow remote code execution.

  • Critical max 9.9
    ICSA-21-315-03 3 CVEs rev. 7

    Siemens SIMATIC WinCC (Update E)

    Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow local or remote attackers to escalate privileges and read, write or delete critical files. Siemens has released updates for several affected products and recommends to update to …

    first Nov 9, 2021
  • Critical max 9.8

    Siemens CPCI85 Firmware of SICAM A8000 Devices

    The CPCI85 firmware of SICAM A8000 CP-8031 and CP-8050 is affected by unauthenticated command injection vulnerability. This could allow an attacker to perfom remote code execution. Siemens has released updates for the affected products and recommends to updat…

  • Critical max 8.8

    mySCADA myPRO

    Successful exploitation of this vulnerability could allow an authenticated user to inject arbitrary operating system commands.

  • Critical

    Industrial Control Links ScadaFlex II SCADA Controllers

    Successful exploitation of this vulnerability could allow an authenticated attacker to overwrite, delete, or create files.

  • Critical max 9.9

    Hitachi Energy MicroSCADA System Data Manager SDM600

    Successful exploitation of these vulnerabilities could allow an attacker to take remote control of the product.

  • Critical max 9.3

    Nexx Smart Home Device

    Successful exploitation of these vulnerabilities could allow an attacker to receive sensitive information, execute application programmable interface (API) requests, or hijack devices.

  • Critical max 6.9

    Honeywell OneWireless Wireless Device Manager

    Successful exploitation of these vulnerabilities could disclose sensitive information, allow privilege escalation, or allow remote code execution.

  • Critical max 9.8
    ICSA-22-342-02 3 CVEs rev. 2

    AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere

    This updated advisory is a follow-up to the original advisory titled ICSA-22-342-02 AVEVA InTouch Access Anywhere, published December 8, 2022 on the ICS webpage at cisa.gov/topics/industrial-control-systems.

    first Dec 8, 2022
  • Critical max 9.8

    Rockwell Automation ThinManager

    Successful exploitation of these vulnerabilities could allow an attacker to potentially perform remote code execution on the target or crash the software.

  • Critical max 9.1

    Omron CJ1M PLC

    Successful exploitation of these vulnerabilities could allow an attacker to bypass user memory protections by writing to a specific memory address. An attacker can also overwrite passwords and lock engineers from reading their own memory regions.

  • Critical max 9.8
    ICSA-23-068-01 13 CVEs

    Akuvox E11

    Successful exploitation of these vulnerabilities could cause loss of sensitive information, unauthorized access, and grant full administrative control to an attacker.

  • Critical max 9.8

    AVEVA Plant SCADA and AVEVA Telemetry Server

    Successful exploitation of this vulnerability could allow an unauthenticated user to read data, cause a denial of service, and tamper with alarm states.

  • Critical max 9.8
    ICSA-23-080-02 13 CVEs

    Delta Electronics InfraSuite Device Master

    Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to obtain access to files and credentials, escalate privileges, and remotely execute arbitrary code.

  • Critical max 7.5
    ICSA-21-194-07 2 CVEs rev. 5

    Siemens Industrial Products LLDP (Update D)

    There are multiple vulnerabilities in an underlying Link Layer Discovery Protocol (LLDP) third party library. Siemens has released updates for the affected products and recommends to update to the latest versions.

    first Jul 13, 2021
  • Critical max 10.0
    ICSA-22-195-12 3 CVEs rev. 3

    Siemens SRCS VPN Feature in SIMATIC CP Devices

    The below referenced devices contain multiple vulnerabilities that could be exploited when the SINEMA Remote Connect Server (SRCS) VPN feature is used. The feature is not activated by default. The most severe could allow an attacker to execute arbitrary code …

    first Jul 12, 2022
  • Critical max 9.8
    ICSA-23-075-01 65 CVEs 1 exploited

    Siemens SCALANCE, RUGGEDCOM Third-Party

    Multiple third-party component vulnerabilities were reported for the Busybox applet, the Linux Kernel, OpenSSL, OpenVPN and various other components used by the RUGGEDCOM and SCALANCE products. The vulnerabilities range from improper neutralization of special…

  • Critical max 8.1

    Baicells Nova

    Successful exploitation of this vulnerability could allow commands performed using pre-login execution and with root permissions.

  • Critical max 5.5

    Mitsubishi Electric MELSOFT iQ AppPortal

    Successful exploitation of these vulnerabilities could allow a malicious attacker to make unidentified impacts such as authentication bypass, information disclosure, denial-of-service, or bypass IP address authentication.

  • Critical max 9.8

    PTC ThingWorx Edge

    Successful exploitation of these vulnerabilities could allow an attacker to crash the device they accessed or could allow remote code execution.

    PTC
  • Critical max 9.3

    Weintek EasyBuilder Pro cMT Series

    Successful exploitation of this vulnerability could allow an attacker to gain control of the user's machine or gain sensitive information.

  • Critical max 9.3
    ICSA-22-314-04 1 CVE rev. 2

    Siemens SINUMERIK ONE and SINUMERIK MC

    SINUMERIK ONE and SINUMERIK MC products are affected by a weak key protection vulnerability in the integrated S7-1500 CPU. The weak key protection vulnerability in the integrated S7-1500 CPU is documented in more detail in SSA-568427 [1]. Siemens has released…

    first Nov 8, 2022
  • Critical
    ICSA-22-314-10 13 CVEs rev. 2

    Siemens SCALANCE W1750D

    The SCALANCE W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to denial of service, unauthenticated remote code execution or stored XSS. Siemens has rel…

    first Nov 8, 2022
  • Critical max 9.8

    Siemens Brownfield Connectivity Client

    Siemens has released a new version for Brownfield Connectivity - Client that contains fixes for multiple vulnerabilities in the underlying OpenSSL library. Successful exploitation of these vulnerabilities could lead to Denial of Service (DoS). Siemens has rel…

  • Critical max 10.0

    Siemens COMOS

    COMOS is affected by memory corruption vulnerability in the cache validation service that could allow an attacker to execute arbitrary code or cause denial of service condition. Siemens has released updates for the affected products and recommends to update t…

  • Critical max 9.1

    Control By Web X-400, X-600M

    Successful exploitation of these vulnerabilities could allow an attacker to inject malicious JavaScript and execute arbitrary code remotely, which could result in a loss of sensitive information.

  • Critical max 9.8

    LS ELECTRIC XBC-DN32U

    Successful exploitation of these vulnerabilities could allow an attacker to steal Programmable Logic Controller (PLC) information, cause users to lose communication with the PLC, modify PLC code, obtain credentials, and create a denial-of-service condition.

  • Critical max 8.1

    Baicells Nova

    Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands.

  • Critical max 9.8
    ICSA-22-221-01 2 CVEs rev. 4

    Mitsubishi Electric Multiple Factory Automation Products (Update B)

    Successful exploitation of these vulnerabilities could create a denial-of-service condition or enable arbitrary code execution.

    first Aug 30, 2022
  • Critical max 8.8

    Delta Electronics DVW-W02W2-E2

    Successful exploitation of this vulnerability could allow a threat actor with low privileges to gain root access to the device, which could then allow them to send malicious commands to managed devices.

  • Critical max 9.0

    Delta Electronics DX-2100-L1-CN

    Successful exploitation of these vulnerabilities could allow an attacker with low privileges to gain root access or allow an unauthenticated attacker to perform remote code execution.

  • Critical max 9.8

    Rockwell Automation products using GoAhead Web Server

    Successful exploitation of these vulnerabilities could have a high impact on the confidentiality, integrity, and availability of the vulnerable devices.

  • Critical max 9.8
    ICSA-22-347-03 5 CVEs rev. 2

    Contec CONPROSYS HMI System (CHS)

    Successful exploitation of these vulnerabilities could allow a remote attacker to send specially crafted requests and cause a loss of sensitive information.

    first Dec 13, 2022
  • Critical max 9.8
    ICSA-22-298-07 10 CVEs rev. 2

    Delta Electronics InfraSuite Device Master

    Successful exploitation of these vulnerabilities could allow an unauthenticated attacker to remotely execute code, cause a denial-of-service condition by remotely deleting files or changing group privileges, or remotely read and write files, all with local ad…

    first Oct 25, 2022
  • Critical max 9.8

    GE Digital Proficy Historian

    Successful exploitation of these vulnerabilities could crash the device after access, cause a buffer overflow condition, and allow remote code execution.

  • Critical max 10.0

    Sewio RTLS Studio

    Successful exploitation of these vulnerabilities could allow an attacker to obtain unauthorized access to the server, alter information, create a denial-of-service condition, gain escalated privileges, and execute arbitrary code.

  • Critical max 10.0

    InHand Networks InRouter

    Successful exploitation of these vulnerabilities could allow a message queuing telemetry transport (MQTT) command injection, unauthorized disclosure of sensitive device information, and remote code execution. If properly chained, these vulnerabilities could r…

  • Critical max 9.8

    SAUTER Controls Nova 200 - 220 Series (PLC 6)

    Successful exploitation of these vulnerabilities could allow unauthorized visibility to sensitive information and remote code execution.