Skip to content
OpenAdvisories

Source

CISA ICS & IT advisories

Source: https://www.cisa.gov/news-events/cybersecurity-advisories

1,944 results · Clear filters · Feed

  • High max 7.3
    ICSA-25-266-03 1 CVE rev. 2

    Schneider Electric SESU

    Schneider Electric is aware of a vulnerability in the Schneider Electric Software Update product (also referred to as “SESU”). The main purpose of the SESU software is to notify customers on the availability of hotfixes or new versions to download and install…

    first Aug 12, 2025
  • High max 7.8
    ICSA-24-102-08 1 CVE rev. 8

    Siemens OPC Foundation Local Discovery Server Affecting Siemens Products

    A vulnerability was identified in OPC Foundation Local Discovery Server which also affects Siemens products that could allow an attacker to escalate privileges under certain circumstances. Siemens has released new versions for several affected products and re…

    first Apr 11, 2023
  • High max 8.8
    ICSA-25-072-03 19 CVEs rev. 3

    Siemens SIMATIC S7-1500 TM MFP

    Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.

    first Mar 11, 2025
  • High max 8.1

    Siemens SIMOTION Tools

    Several tools for the SIMOTION system are affected by a local privilege escalation vulnerability. This could allow an attacker to execute arbitrary code with SYSTEM privileges when a legitimate user installs an application that uses the affected setup compone…

  • High max 7.5

    Siemens Industrial Edge Management

    Industrial Edge Management is affected by a vulnerability that could allow a remote attacker to cause a denial of service condition. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.

  • High max 7.8

    Fuji Electric FRENIC-Loader 4

    Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code.

  • High max 7.3

    Mitsubishi Electric MELSEC iQ-F Series CPU Module

    Successful exploitation of this vulnerability could allow an attacker to read or write the device values of the product. In addition, the attacker may be able to stop the operation of the programs.

  • High max 7.5

    Mitsubishi Electric MELSEC iQ-F Series CPU Module

    Successful exploitation of this vulnerability could allow an attacker the ability to obtain credential information by intercepting SLMP communication messages, and read or write the device values of the product by using the obtained credential information. In…

  • High max 7.3

    Delta Electronics CNCSoft-G2

    Successful exploitation of this vulnerability could allow attackers to execute arbitrary code on affected installations of the device.

  • High max 8.6

    Delta Electronics COMMGR

    Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code.

  • High max 5.3

    GE Vernova CIMPLICITY

    Successful exploitation of this vulnerability could allow a low-privileged local attacker to escalate privileges.

  • High max 8.2
    ICSA-25-273-02 4 CVEs rev. 3

    Festo SBRD-Q/SBOC-Q/SBOI-Q

    The affected product families are cameras SBOC/SBOI and the Controller SBRD. The vulnerabilities are located within the Ethernet IP Stack from EIPStackGroup OpENer Ethernet/IP.

    first Sep 22, 2021
  • High max 7.5
    ICSA-25-182-06 1 CVE rev. 2

    Hitachi Energy Relion 670/650 and SAM600-IO Series (Update A)

    Hitachi Energy is aware of a vulnerability that affects the Relion 670/650 and SAM600-IO series IED device versions that are listed in this document. An authenticated attacker successfully exploiting this vulnerability via FTP access can cause the device to r…

    first Jun 24, 2025
  • High max 8.8

    Multiple Open-Source Software Vulnerabilities in Hitachi Energy Asset Suite Product

    Hitachi Energy is aware of multiple reported vulnerabilities that affect the Asset Suite product versions mentioned in this document below. If exploited these vulnerabilities can potentially impact on confidentiality, integrity and availability of the product…

  • High max 8.7
    ICSA-25-140-03 3 CVEs rev. 2

    Danfoss AK-SM 8xxA Series (Update A)

    Successful exploitation of these vulnerabilities could enable a remote attacker to bypass authentication and remotely execute arbitrary code.

    first May 20, 2025
  • High max 7.8

    INVT VT-Designer and HMITool

    Successful exploitation of these vulnerabilities could allow attackers to execute arbitrary code in the context of the current process.

  • High max 8.1
    VA-25-239-01 4 CVEs

    Agiloft multiple vulnerabilities

    Agiloft is a web-based contract management platform. Multiple vulnerabilities were found in Agiloft that could allow an attacker to gain administrative access to Agiloft, execute operating system commands, or modify update packages.

  • High max 8.5
    ICSA-25-226-30 1 CVE rev. 2

    Rockwell Automation FactoryTalk Action Manager

    Successful exploitation of this vulnerability could allow a local unauthenticated attacker to listen to communications and manipulate the device.

    first Aug 14, 2025
  • High max 8.5

    Rockwell Automation FactoryTalk Viewpoint

    Successful exploitation of this vulnerability could result in full privilege escalation.

  • High max 8.8

    Rockwell Automation ArmorBlock 5000 I/O - Webserver

    Successful exploitation of these vulnerabilities could allow an attacker to predict session numbers or perform privileged actions.

  • High max 7.3

    Rockwell Automation Studio 5000 Logix Designer

    Successful exploitation of this vulnerability could allow an attacker to crash the device or execute malicious code.

  • High max 8.2

    Siemens Desigo CC Product Family and SENTRON Powermanager

    Versions V5.0 through V8 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems…

  • High max 7.8

    Ashlar-Vellum Cobalt, Xenon, Argon, Lithium, Cobalt Share

    Successful exploitation of these vulnerabilities could allow an attacker to disclose information and execute arbitrary code.

  • High max 7.1

    AVEVA PI Integrator

    Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, or upload and execute files.

  • High max 7.5

    Santesoft Sante PACS Server

    Successful exploitation of these vulnerabilities could allow an attacker to create arbitrary files, cause a denial-of-service condition, obtain sensitive information, and steal a user's cookie information.

  • High max 8.8
    ICSA-17-271-01B 1 CVE rev. 4

    Siemens Ruggedcom ROS, SCALANCE

    The RUGGEDCOM RCDP protocol is not properly configured after commissioning of RUGGEDCOM ROS based devices and some SCALANCE X switch models and could allow unauthenticated remote users to perform administrative operations. An attacker must be in the same adja…

    first Sep 28, 2017
  • High max 8.0
    ICSA-22-195-18 1 CVE rev. 6

    Siemens RUGGEDCOM ROS Code Injection

    RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the Command Line Interface (CLI). Siemens has released new versions for several affected products and recommends …

    first Jul 12, 2022
  • High max 7.5
    ICSA-23-222-08 1 CVE rev. 3

    Siemens RUGGEDCOM ROS Devices

    A denial of service vulnerability could allow an unauthorized attacker to cause total loss of availability in the web server of the affected devices. Siemens has released new versions for several affected products and recommends to update to the latest versio…

    first Aug 8, 2023
  • High max 8.8
    ICSA-24-193-06 4 CVEs rev. 2

    Siemens RUGGEDCOM

    Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information. Siemens has released new versions for several affected products and recommends to update to the latest…

    first Jul 9, 2024
  • High max 7.8
    ICSA-24-347-05 1 CVE rev. 2

    Siemens Siemens Engineering Platforms

    Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected pr…

    first Dec 10, 2024
  • High max 7.5
    ICSA-25-044-05 1 CVE rev. 5

    Siemens SIPROTEC 5 Devices

    An information disclosure vulnerability in SIPROTEC 5 devices could allow an unauthenticated, remote attacker to retrieve sensitive information of the device. Siemens has released new versions for the affected products and recommends to update to the latest v…

    first Feb 11, 2025
  • High max 8.1

    Siemens COMOS

    COMOS before V10.6 is affected by a local arbitrary code execution vulnerability in the integrated Open Design Alliance Drawings SDK. Siemens has released a new version for COMOS and recommends to update to the latest version.

  • High max 7.8

    Siemens Simcenter Femap

    Simcenter Femap contains a file parsing vulnerability that could be triggered when the application reads files in STP or BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or …

  • High max 7.1

    Siemens Opcenter Quality

    The Opcenter Quality is affected by multiple vulnerabilities in the SmartClient modules Opcenter QL Home (SC), SOA Audit and SOA Cockpit. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • High max 6.9

    Siemens RUGGEDCOM CROSSBOW Station Access Controller

    RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code or to create a denial of service condition. Siemens has released a new version for R…

  • High max 7.5

    Siemens SIPROTEC 4 and SIPROTEC 4 Compact

    SIPROTEC 4 and SIPROTEC 4 Compact devices contain a vulnerability that could allow an unauthenticated remote attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the lates…

  • High max 7.8

    Siemens SINEC Traffic Analyzer

    SINEC Traffic Analyzer before V3.0 is affected by multiple vulnerabilities. Siemens has released a new version for SINEC Traffic Analyzer and recommends to update to the latest version. Siemens is preparing further fix versions and recommends countermeasures …

  • High max 8.3

    Siemens SINUMERIK

    Siemens SINUMERIK Controllers are affected by an improper VNC password check vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.

  • High max 7.6

    Siemens RUGGEDCOM ROX II

    RUGGEDCOM ROX II devices do not properly limit access through their Built-In-Self-Test (BIST) mode. This could allow a local attacker to bypass authentication and access a root shell on the device. Siemens is preparing fix versions and recommends specific cou…

  • High max 8.4

    Rockwell Automation Arena

    Successful exploitation of these vulnerabilities could allow an attacker to disclose information and execute arbitrary code.