Skip to content
OpenAdvisories

Vendor

Danfoss

14 known vulnerabilities.

Danfoss at a glance

Last 12 months
1
Critical · all time
6
Exploited · all time
0
Public exploit · all time
1
New vulnerabilities per month · last 12 months
0 1 1 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 0 vulnerabilities June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 1 vulnerability, 1 critical September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202611
Jul 202600
Jun 202600
May 202600
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202500
Aug 202520
Jul 202500
Jun 202500
May 202510
Apr 202500
Mar 202500
Feb 202500
Jan 202500
Dec 202400

Latest advisories

  • High max 8.7
    ICSA-25-140-03 3 CVEs rev. 2

    Danfoss AK-SM 8xxA Series (Update A)

    Successful exploitation of these vulnerabilities could enable a remote attacker to bypass authentication and remotely execute arbitrary code.

    first May 20, 2025

14 results · Feed

  • Critical 9.3

    Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software

    Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data a…

  • Medium 6.8

    Post auth nginx configuration injection in Danfoss AK-SM8xxA Series

    Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which could allow for a denial of service attack induced by improper handling of exceptional conditions

  • High 8.7

    Post-Authentication OS Command Injection RCE in Danfoss AK-SM8xxA Series

    Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command ('Command Injection') in Danfoss AK-SM8xxA Series prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system.

  • High 8.2
    CVE-2025-41450 Public exploit

    Authentication bypass with privileged access in Danfoss AK-SM 8xxA Series prior to version 4.2

    Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2

  • High 7.5

    Authentication Bypass in Danfoss AK-SM800A

    Because of an authentication flaw an attacker would be capable of generating a web report that discloses sensitive information such as internal IP addresses, usernames, store names and other sensitive information.

  • High 8.8

    Authneticated Path Traversal in Danfoss AK-SM800A

    Due to improper restriction, authenticated attackers could retrieve and read system files of the underlying server through the XML interface. The information that can be read can lead to a full system compromise.

  • Critical 9.9

    Authenticated Remote Command Execution in Danfoss AK-SM800A

    Due to improper input validation, an authenticated remote attacker could execute arbitrary commands on the target system.

  • Critical 9.9

    Authenticated OS Command Injection in Danfoss AK-EM100

    The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web application parameters.

  • Critical 9.0

    Reflected Cross-Site Scripting in Danfoss AK-EM100

    The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting.

  • Critical 10.0

    SQL Injection in Danfoss AK-EM100

    The Danfoss AK-EM100 web forms allow for SQL injection in the login forms.

  • Medium 5.3

    Webreport disclosure to unauthorized actor in Danfoss AK-EM100

    The webreport generation feature in the Danfoss AK-EM100 allows an unauthorized actor to generate a web report that discloses sensitive information such as the internal IP address, usernames and internal device values.

  • High 7.7

    Local File Inclusion in Danfoss AK-EM100

    The Danfoss AK-EM100 web applications allow for Local File Inclusion in the file parameter.

  • High 7.5

    Cleartext credentials in Danfoss AK-EM100

    The Danfoss AK-EM100 stores login credentials in cleartext.

  • Critical 9.0

    Reflected Cross-Site Scripting in Danfoss AK-EM100

    The Danfoss AK-EM100 web applications allow for Reflected Cross-Site Scripting in the title parameter.