Skip to content
OpenAdvisories

Vendor

Delta Industrial Automation

6 known vulnerabilities.

Delta Industrial Automation at a glance

Last 12 months
0
Critical · all time
0
Exploited · all time
0
Public exploit · all time
1
New vulnerabilities per month · last 12 months
0 1 1 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 0 vulnerabilities June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 0 vulnerabilities September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202600
Jul 202600
Jun 202600
May 202600
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202500
Aug 202500
Jul 202500
Jun 202500
May 202500
Apr 202500
Mar 202500
Feb 202500
Jan 202500
Dec 202400

6 results · Feed

  • High 7.8

    CVE-2023-4685

    Delta Electronics' CNCSoft-B version 1.0.0.4 and DOPSoft versions 4.0.0.82 and prior are vulnerable to stack-based buffer overflow, which could allow an attacker to execute arbitrary code.

  • High 7.8

    CVE-2023-0124

    Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to an out-of-bounds write, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.

  • High 7.8

    CVE-2023-0123

    Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.

  • High 7.8

    CVE-2022-4634

    All versions prior to Delta Electronic’s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.

  • High 7.2
    CVE-2022-4616 Public exploit

    The webserver in Delta DX-3021 versions prior to 1.24 is vulnerable to command injection through the network diagnosis …

  • High 8.1

    ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal

    Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize …