25 known vulnerabilities.

Endress+Hauser at a glance

Last 12 months
1
Critical · all time
2
Exploited · all time
0
Public exploit · all time
0
New vulnerabilities per month · last 12 months
0 1 1 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 0 vulnerabilities June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 1 vulnerability September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202610
Jul 202600
Jun 202600
May 202600
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202510
Aug 202500
Jul 2025190
Jun 202500
May 202500
Apr 202500
Mar 202500
Feb 202500
Jan 202500
Dec 202400

Latest advisories

  • Medium max 6.7
    VDE-2026-065 1 CVE

    Endress+Hauser: iDTM Debug Interface Vulnerability in the FDI Package Library

    A vulnerability in the iDTM FDI allows an attacker with elevated privileges and access to the host system to enable the debug interface by placing a crafted file in the application directory.

  • High max 7.5

    Vulnerability in several Endress+Hauser products

    A vulnerability was discovered in several Endress+Hauser products that can be accessed via ethernet.

  • High max 7.5
    VDE-2026-045 1 CVE

    Endress+Hauser: Multiple products affected by SopasET interface vulnerability

    A vulnerability was discovered in several Endress+Hauser products that can be accessed via ethernet.

  • Critical max 9.3
    SCA-2026-0007 1 CVE 1 exploited

    Sudo vulnerability affects Endress+Hauser MCS200HW

    The display unit of the Endress+Hauser MCS200HW is affected by a sudo chroot vulnerability.

  • Critical max 9.3
    VDE-2026-032 1 CVE 1 exploited

    Endress+Hauser: sudo vulnerability affects Endress+Hauser MCS200HW

    The display unit of the Endress+Hauser MCS200HW is affected by a sudo chroot vulnerability.

25 results · Feed

  • Medium 6.7

    iDTM FDI Unauthorized Debug Interface Enablement

    A vulnerability in the iDTM FDI allows an attacker with elevated privileges and access to the host system to enable the debug interface by placing a crafted file in the application directory, potentially resulting in unauthorized access to connected devices a…

  • High 7.4

    Endress+Hauser: Proline 10 Maintenance credentials may be exposed under certain conditions

    A low-privileged attacker in bluetooth range may be able to access the password of a higher-privilege user (Maintenance) by viewing the device’s event log. This vulnerability could allow the Operator to authenticate as the Maintenance user, thereby gaining un…

  • High 7.6

    CVE-2025-27461

    During startup, the device automatically logs in the EPC2 Windows user without requesting a password.

  • High 7.6

    CVE-2025-27460

    The hard drives of the device are not encrypted using a full volume encryption feature such as BitLocker. This allows an attacker with physical access to the device to use an alternative operating system to interact with the hard drives, completely circumvent…

  • Medium 4.4

    CVE-2025-27459

    The VNC application stores its passwords encrypted within the registry but uses DES for encryption. As DES is broken, the original passwords can be recovered.

  • Medium 6.5

    CVE-2025-27458

    The VNC authentication mechanism bases on a challenge-response system where both server and client use the same password for encryption. The challenge is sent from the server to the client, is encrypted by the client and sent back. The server does the same en…

  • Medium 6.5

    CVE-2025-27457

    All communication between the VNC server and client(s) is unencrypted. This allows an attacker to intercept the traffic and obtain sensitive data.

  • High 7.5

    CVE-2025-27456

    The SMB server's login mechanism does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.

  • Medium 4.3

    CVE-2025-27455

    The web application is vulnerable to clickjacking attacks. The site can be embedded into another frame, allowing an attacker to trick a user into clicking on something different from what the user perceives, thus potentially revealing confidential information…

  • Medium 4.3

    CVE-2025-27454

    The application is vulnerable to cross-site request forgery. An attacker can trick a valid, logged in user into submitting a web request that they did not intend. The request uses the victim's browser's saved authorization to execute the request.

  • Medium 5.3

    CVE-2025-27453

    The HttpOnly flag is set to false on the PHPSESSION cookie. Therefore, the cookie can be accessed by other sources such as JavaScript.

  • Medium 5.3

    CVE-2025-27452

    The configuration of the Apache httpd webserver which serves the MEAC300-FNADE4 web application, is partly insecure. There are modules activated that are not required for the operation of the FNADE4 web application. The functionality of the some modules pose …

  • Medium 5.3

    CVE-2025-27451

    For failed login attempts, the application returns different error messages depending on whether the login failed due to an incorrect password or a non-existing username. This allows an attacker to guess usernames until they find an existing one.

  • Medium 6.5

    CVE-2025-27450

    The Secure attribute is missing on multiple cookies provided by the MEAC300-FNADE4. An attacker can trick a user to establish an unencrypted HTTP connection to the server and intercept the request containing the PHPSESSID cookie.

  • High 7.5

    CVE-2025-27449

    The MEAC300-FNADE4 does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.

  • Medium 6.8

    CVE-2025-27448

    The web application is susceptible to cross-site-scripting attacks. An attacker who can create new dashboards can inject JavaScript code into the dashboard name which will be executed when the website is loaded.

  • High 7.4

    CVE-2025-27447

    The web application is susceptible to cross-site-scripting attacks. An attacker can create a prepared URL, which injects JavaScript code into the website. The code is executed in the victim’s browser when an authenticated administrator clicks the link.

  • Medium 4.3

    CVE-2025-1711

    Multiple services of the DUT as well as different scopes of the same service reuse the same credentials.

  • High 7.5

    CVE-2025-1710

    The maxView Storage Manager does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame, making it susceptible to brute-force attacks.

  • Medium 6.5

    CVE-2025-1709

    Several credentials for the local PostgreSQL database are stored in plain text (partially base64 encoded).

  • High 8.6

    CVE-2025-1708

    The application is vulnerable to SQL injection attacks. An attacker is able to dump the PostgreSQL database and read its content.

  • High 7.5

    CVE-2024-8751

    A vulnerability allows a remote unauthenticated attacker to modify the prod uct’s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.

  • Critical 9.8

    Endress+Hauser: Multiple products are vulnerable to code injection

    An unauthenticated remote attacker can run malicious c# code included in curve files and execute commands in the users context.

  • Medium 6.5

    ENDRESS+HAUSER: Ecograph T utilizing Webserver firmware version 2.x exposures sensitive information to an unauthorized actor

    Endress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) and Memograph M (Neutral/Private Label) (RSG45, ORSG45) with Firmware version V2.0.0 and above is prone to exposure of sensitive information to an unauthorized actor. The firmware release has a…

  • Critical 9.1

    ENDRESS+HAUSER: Ecograph T utilizing Webserver firmware version 1.x has improper privilege management

    Endress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) with Firmware version prior to V2.0.0 is prone to improper privilege management. The affected device has a web-based user interface with a role-based access system. Users with different roles h…