Skip to content
OpenAdvisories

Product · SICK

MSC800

2 known vulnerabilities.

MSC800 at a glance

Last 12 months
0
Critical · all time
0
Exploited · all time
0
Public exploit · all time
0
New vulnerabilities per month · last 12 months
0 1 1 December 2025: 0 vulnerabilities Dec 2025 January 2026: 0 vulnerabilities February 2026: 0 vulnerabilities March 2026: 0 vulnerabilities Mar April 2026: 0 vulnerabilities May 2026: 0 vulnerabilities June 2026: 0 vulnerabilities Jun July 2026: 0 vulnerabilities August 2026: 0 vulnerabilities September 2026: 0 vulnerabilities Sep October 2026: 0 vulnerabilities November 2026: 0 vulnerabilities
Show as table
MonthVulnerabilitiesCritical
Nov 202600
Oct 202600
Sep 202600
Aug 202600
Jul 202600
Jun 202600
May 202600
Apr 202600
Mar 202600
Feb 202600
Jan 202600
Dec 202500
Nov 202500
Oct 202500
Sep 202500
Aug 202500
Jul 202500
Jun 202500
May 202500
Apr 202500
Mar 202500
Feb 202500
Jan 202500
Dec 202400

Latest advisories

  • High max 7.5
    SCA-2024-0002 1 CVE rev. 2

    Vulnerability in SICK MSC800

    SICK found a security vulnerability in the SICK MSC800. This vulnerability allows an unauthenticated attacker to modify the IP address of the product through the SopasET interface, potentially leading to Denial of Service. Currently SICK is not aware of any p…

  • Medium
    SCA-2022-0006 1 CVE rev. 3

    Vulnerability in SICK MSC800

    SICK received a report about a vulnerability in the SICK MSC800. An attacker could compromise services on the MSC800 by a TCP sequence prediction attack if a vulnerable version is used.

  • High
    SCA-2020-0004 1 CVE rev. 3

    Vulnerability in Platform Mechanism AutoIP

    SICK received a report from IOActive that informed SICK about a security vulnerability within the platform mechanism AutoIP, used by multiple devices. SICK recommends updating to the newest version. Refer to the recommended remediations for affected products …

  • Critical

    SICK MSC800

    Successful exploitation of this vulnerability could allow a low-skilled remote attacker to reconfigure settings and/or disrupt the functionality of the device.

  • Critical
    SCA-2019-0001 1 CVE rev. 3

    MSC800 affected by hard-coded credentials vulnerability

    The ICS-CERT reported a security vulnerability that affects MSC800 versions before 4.0. The MSC800 uses hard-coded credentials, which potentially allow low-skilled remote attackers to reconfigure settings and /or disrupt the functionality of the device. Curre…

2 results · Feed

  • High 7.5

    CVE-2024-8751

    A vulnerability allows a remote unauthenticated attacker to modify the prod uct’s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.

  • Unscored —

    SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account pas…