SIMATIC ET 200SP Open Controller CPU 1515SP PC3 V4 CPUs at a glance
- Last 12 months
- 12
- Critical · all time
- 6
- Exploited · all time
- 0
- Public exploit · all time
- 0
Show as table
| Month | Vulnerabilities | Critical |
|---|---|---|
| Nov 2026 | 0 | 0 |
| Oct 2026 | 8 | 3 |
| Sep 2026 | 0 | 0 |
| Aug 2026 | 0 | 0 |
| Jul 2026 | 0 | 0 |
| Jun 2026 | 0 | 0 |
| May 2026 | 3 | 2 |
| Apr 2026 | 0 | 0 |
| Mar 2026 | 1 | 1 |
| Feb 2026 | 0 | 0 |
| Jan 2026 | 0 | 0 |
| Dec 2025 | 0 | 0 |
| Nov 2025 | 0 | 0 |
| Oct 2025 | 0 | 0 |
| Sep 2025 | 0 | 0 |
| Aug 2025 | 0 | 0 |
| Jul 2025 | 0 | 0 |
| Jun 2025 | 0 | 0 |
| May 2025 | 0 | 0 |
| Apr 2025 | 0 | 0 |
| Mar 2025 | 0 | 0 |
| Feb 2025 | 0 | 0 |
| Jan 2025 | 0 | 0 |
| Dec 2024 | 0 | 0 |
Most common weaknesses
Latest advisories
-
Critical max 9.6
Siemens SIMATIC S7 PLCs Web Server
SIMATIC S7-1500 devices contain multiple vulnerabilities in the web server that could allow an attacker to execute malicious code in an authorized user’s browser session and perform PLC operations within the scope of that user’s authorization. Siemens is prep…
first Oct 13, 2026 -
High max 9.8NCSC-2026-0415 41 CVEs
Kwetsbaarheden verholpen in Siemens-producten
Siemens heeft kwetsbaarheden verholpen in diverse producten zoals Desigo, Industrial Plus, RUGGEDCOM, SIMATIC en SIPLUS.
-
Critical max 9.6SSA-591731 8 CVEs
SSA-591731: Multiple Vulnerabilities in SIMATIC S7 PLCs Web Server
SIMATIC S7-1500 devices contain multiple vulnerabilities in the web server that could allow an attacker to execute malicious code in an authorized user’s browser session and perform PLC operations within the scope of that user’s authorization. Siemens is prep…
-
Critical max 9.1
SSA-688146: Multiple Cross-Site Scripting Vulnerabilities in SIMATIC S7 PLCs Web Server
SIMATIC S7 PLCs contain multiple vulnerabilities in the web server that could allow an attacker to perform cross-site scripting attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens i…
first May 12, 2026 -
Critical max 9.6
Siemens SIMATIC
SIMATIC S7-1500 devices contain a vulnerability that could allow an attacker to inject code by tricking a legitimate user into importing a specially crafted trace file in the web interface. Siemens has released new versions for several affected products and r…
first Mar 10, 2026
12 results · Feed
-
Medium 6.1
Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before r…
-
Medium 6.1
Affected devices do not properly sanitize calculated signal names contained in imported CSV trace files before includin…
-
Medium 6.1
Affected devices do not properly sanitize signal names contained in imported CSV trace files before rendering them in s…
-
Critical 9.6
Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before …
-
Critical 9.6
Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the…
-
Medium 6.1
Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering…
-
Medium 6.1
Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CS…
-
Critical 9.6
Affected devices do not properly restrict executable content contained in imported trace files. This could allow an att…
-
High 7.1
Affected devices do not properly validate and sanitize filenames on the Firmware Update page. This could allow a remote…
-
Critical 9.1
Affected devices do not properly validate and sanitize Technology Object (TO) name rendered on the "Motion Control Diag…
-
Critical 9.1
Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page…
-
Critical 9.6
Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through …