27 results · Clear filters · Feed
-
High 8.8
Tenda AC7 POST Request SetSysTimeCfg fromSetSysTime memory corruption
A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflo…
-
High 8.8
Tenda AC7 setNotUpgrade stack-based overflow
A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. Th…
-
High 8.8
Tenda AC7 saveAutoQos stack-based overflow
A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit…
-
High 8.8
Tenda AC7 fast_setting_pppoe_set stack-based overflow
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launc…
-
High 8.8
Tenda AC7 WifiMacFilterSet stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remo…
-
High 8.8
Tenda AC7 SetUpnpCfg stack-based overflow
A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been d…
-
High 8.8
Tenda AC7 SetDDNSCfg stack-based overflow
A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been …
-
High 8.8
Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely.…
-
High 8.8CVE-2025-8017 EPSS 13%
Tenda AC7 httpd setMacFilterCfg formSetMacFilterCfg stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based b…
-
High 8.8
Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated…
-
High 8.8
Tenda AC7 AdvSetLanip fromadvsetlanip buffer overflow
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be i…
-
High 8.8
Tenda AC7 SetRebootTimer formSetRebootTimer stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffe…
-
High 8.8
Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is …
-
High 8.8
Tenda AC7 SetPptpServerCfg formSetPPTPServer buffer overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to…
-
High 8.8
Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It …
-
High 8.8
Tenda AC7 GetParentControlInfo stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is po…
-
High 8.8
Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack…
-
High 8.8
Tenda AC7 openSchedWifi setSchedWifi stack-based overflow
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The…
-
High 8.8
Tenda AC7 saveParentControlInfo stack-based overflow
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer o…
-
High 8.8
Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buff…
-
High 8.8
Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The…
-
High 8.8
Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may b…
-
High 8.8
Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attac…
-
High 8.8
Tenda AC7 SetNetControlList formSetQosBand stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible …
-
High 8.8
Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The at…
-
High 8.8
Tenda AC7 setcfm formSetCfm stack-based overflow
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The atta…
-
High 8.8
Tenda AC7 QuickIndex formQuickIndex stack-based overflow
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible …