0751-9x01 at a glance
- Last 12 months
- 1
- Critical · all time
- 1
- Exploited · all time
- 0
- Public exploit · all time
- 0
Show as table
| Month | Vulnerabilities | Critical |
|---|---|---|
| Nov 2026 | 0 | 0 |
| Oct 2026 | 1 | 1 |
| Sep 2026 | 0 | 0 |
| Aug 2026 | 0 | 0 |
| Jul 2026 | 0 | 0 |
| Jun 2026 | 0 | 0 |
| May 2026 | 0 | 0 |
| Apr 2026 | 0 | 0 |
| Mar 2026 | 0 | 0 |
| Feb 2026 | 0 | 0 |
| Jan 2026 | 0 | 0 |
| Dec 2025 | 0 | 0 |
| Nov 2025 | 0 | 0 |
| Oct 2025 | 0 | 0 |
| Sep 2025 | 0 | 0 |
| Aug 2025 | 0 | 0 |
| Jul 2025 | 0 | 0 |
| Jun 2025 | 0 | 0 |
| May 2025 | 0 | 0 |
| Apr 2025 | 0 | 0 |
| Mar 2025 | 0 | 0 |
| Feb 2025 | 0 | 0 |
| Jan 2025 | 0 | 0 |
| Dec 2024 | 0 | 0 |
Most common weaknesses
Latest advisories
-
Critical max 9.8VDE-2025-102 1 CVE
WAGO: Multiple Devices are affected by a Vulnerability in BACnet IP Stack
Multiple WAGO devices are affected by a vulnerability in the dynamic creation of BACnet File Objects. The object name is used as a file path without sufficient validation and is not restricted to the intended directory, so relative paths can be used to reach …
-
Medium max 6.5
WAGO: Year 2038 problem
The Year 2038 Problem affects systems using a 32-bit integer to represent time as the number of seconds since January 1, 1970. On January 19, 2038, at 03:14:07 UTC, the time value will exceed the maximum for a 32-bit integer, causing an overflow and resetting…
first Apr 15, 2025 -
High max 7.2VDE-2024-008 1 CVE
Wago: Vulnerability in WBM through Open VPN
A security vulnerability has been identified in the Web-Based Management (WBM) function when OpenVPN is enabled.
-
Medium max 6.5
WAGO: Vulnerabilities in WAGO Device Manager
Vulnerabilities have been discovered in the WAGO Device Manager that allow any origin to access the server and set header values, as well as an endpoint that permits read access to the file system. The WAGO Device Manager is a software for configuring and par…
first Jun 16, 2025 -
High max 7.5VDE-2025-062 3 CVEs
WAGO: Multiple Vulnerabilities in CODESYS components
Several WAGO firmwares installed on different devices are impacted by various CODESYS vulnerabilities. These affect the runtime, visualization, and OPC UA server.
1 result · Feed
-
Critical 9.8
Path traversal in dynamically created BACnet File Objects
The object name of a dynamically created BACnet File Object is interpreted as a file path without sufficient validation. Because relative paths are not limited to the intended directory, an unauthenticated remote attacker can traverse outside of it and read o…