Vendor
Hitachi Energy
118 known vulnerabilities.
Products
118 results · Feed
-
Medium 6.9
A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password…
-
High 7.5
A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The v…
-
High 7.5
A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. T…
-
Critical 9.0
A vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment a…
-
Medium 4.0
A vulnerability exists in a FOXMAN-UN and UNEM logging component, it only affects systems that use remote authenticatio…
-
High 7.5
SDM600 software privilege level
A vulnerability exists in the SDM600 software. The software operates at a privilege level that is higher than the minimum level required. An attacker who successfully exploits this vulnerability can escalate privileges. This issue affects: All SDM600 versions…
-
Medium 4.8
SDM600 API permission check
A vulnerability exists in a SDM600 endpoint. An attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive. This issue affects: All SDM600 versions prior to versi…
-
High 7.5
SDM600 endpoint vulnerability
A vulnerability exists in a SDM600 endpoint. An attacker could exploit this vulnerability by running multiple parallel requests, the SDM600 web services become busy rendering the application unresponsive. This issue affects: All SDM600 versions prior to versi…
-
High 7.7
SDM600 API web services authorization validation
A vulnerability exists in the SDM600 API web services authorization validation implementation. An attacker who successfully exploits the vulnerability could read data directly from a data store that is not restricted, or insufficiently protected, having acces…
-
Critical 9.9
SDM600 file permission validation
A vulnerability exists in the SDM600 file permission validation. An attacker could exploit the vulnerability by gaining access to the system and uploading a specially crafted message to the system node, which could result in Arbitrary code Executing. This iss…
-
Medium 5.9
IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products
A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. An attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to st…
-
Medium 5.7
A vulnerability exists in the Lumada APM’s User Asset Group feature due to a flaw in access control mechanism implementation on the “Limited Engineer” role.
A vulnerability exists in the affected versions of Lumada APM’s User Asset Group feature due to a flaw in access control mechanism implementation on the “Limited Engineer” role, granting it access to the embedded Power BI reports feature. An attacker that man…
-
High 8.3
Communication between the client and server partially using CORBA over TCP/IP
Communication between the client and the server application of the affected products is partially done using CORBA (Common Object Request Broker Architecture) over TCP/IP. This protocol is not encrypted and allows tracing of internal messages. This issue affe…
-
High 7.1
Hardcoded credential is found in the message queue
Hardcoded credential is found in affected products' message queue. An attacker that manages to exploit this vulnerability will be able to access data to the internal message queue. This issue affects * FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN…
-
High 8.0
The affected products store public and private key that are used to sign and protect custom parameter set files from modification.
The affected products store both public and private key that are used to sign and protect Custom Parameter Set (CPS) file from modification. An attacker that manages to exploit this vulnerability will be able to change the CPS file, sign it so that it is trus…
-
High 7.1
Use of default key for encryption
In the DES implementation, the affected product versions use a default key for encryption. Successful exploitation allows an attacker to obtain sensitive information and gain access to the network elements that are managed by the affected products versions. T…
-
High 7.1
Weak DES encryption
DES cipher, which has inadequate encryption strength, is used Hitachi Energy FOXMAN-UN to encrypt user credentials used to access the Network Elements. Successful exploitation allows sensitive information to be decrypted easily. This issue affects * FOXMAN-U…
-
High 7.1
Cleartext Credentials Vulnerability on Hitachi Energy’s Multiple IED Connectivity Packages (IED ConnPacks) and PCM600 Products
A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in …
-
High 8.8
Input Validation Vulnerability in Hitachi Energy’s MicroSCADA Pro/X SYS600 Products
An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. An authenticated user can launch an administrator level remote code execution irrespective of the authenticated user's role.
-
Medium 5.3
A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected conne ...
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connect…
-
High 7.5
A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by ...
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator acces…
-
High 7.5
A vulnerability exists in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS ...
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability…
-
High 7.5
A vulnerability exists in the ICCP stack of the affected SYS600 versions due to validation flaw in the process that establishes the ICCP communication. The validation flaw will cause a denial-of-service when ICCP of SYS600 is request to forward any da ...
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too di…
-
High 8.5
A vulnerability exists in the Workplace X WebUI in which an authenticated user is able to execute any MicroSCADA internal scripts irrespective of the authenticated user's role.
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated user's role. This issue affects: Hitachi E…
-
Medium 5.0
HTTP Response Splitting in Hitachi Energy’s MSM Product
A vulnerability exists in the http web interface where the web interface does not validate data in an HTTP header. This causes a possible HTTP response splitting, which if exploited could lead an attacker to channel down harmful code into the user’s web brows…
-
Medium 5.0
Cross Site Request Forgery (CSRF) in Hitachi Energy’s MSM Product
A vulnerability exists in the HTTP web interface where the web interface does not sufficiently verify if a well-formed, valid, consistent request was intentionally provided by the user who submitted the request. This cause a Cross Site Request Forgery (CSRF),…
-
Medium 6.0
User authentication bypass in TXpert Hub CoreTec 4
A vulnerability in the application authentication and authorization mechanism in Hitachi Energy's TXpert Hub CoreTec 4, that depends on a token validation of the session identifier, allows an unauthorized modified message to be executed in the server enabling…
-
Unscored —
Remote Code Execution in TXpert Hub CoreTec 4
Improper Input Validation vulnerability in a particular configuration setting field of Hitachi Energy TXpert Hub CoreTec 4 product, allows an attacker with access to an authorized user with ADMIN or ENGINEER role rights to inject an OS command that is execute…
-
Unscored —
Firmware upload verification bypass in TXpert Hub CoreTec 4
A vulnerability exists in the file upload validation part of Hitachi Energy TXpert Hub CoreTec 4 product. The vulnerability allows an attacker or malicious agent who manages to gain access to the system and obtain an account with sufficient privilege to uploa…
-
High 7.5
Specially Crafted Modbus TCP Packet Vulnerability in RTU500 series
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing th…
-
Medium 4.2
OWASP Related Vulnerabilities in Hitachi Energy’s LinkOne Product
Cross-site Scripting (XSS) vulnerability in Hitachi Energy LinkOne allows an attacker that manages to exploit the vulnerability can take advantage to exploit multiple web attacks and stole sensitive information. This issue affects: Hitachi Energy LinkOne 3.20…
-
Critical 9.0
Weak default credential associated with TCP port 26
Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. This issue affects: Hitachi Energy FOX61x versions prior to R15A. Hitachi En…
-
High 8.6
SSH activation problem in the proprietary management protocol (port TCP 5558)
Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP 5558 to cause disruption to the NMS and NE communication. Thi…
-
High 7.5
Specially Crafted IEC 60870-5-104 Packet Vulnerability in RTU500 series
Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot w…
-
High 7.2
Insufficient Security Control Vulnerability
Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited this vulnerability, of which the product does not sufficiently …
-
High 8.1
Insufficient Security Control Vulnerability
Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tin…
-
High 7.2
Authentication Bypass Vulnerability Vulnerability in Retail Operations Product and Counterparty Settlement and Billing (CSB)
Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) allows an attacker to execute a modified signed Java Applet JAR file. A successful exploit…
-
Medium 6.7
Certificate verification vulnerability in Update Manager of PCM600 Engineering Tool
A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed.